  1. bellairaphon

    heating problem after adding extra rad

    Shut the rads upstairs. Then balance the system. Probably just a partial airlock.
  2. bellairaphon

    3 Port Valve problems

    The balancing valve sounds like bypass valve which needs to be closed as not required with a 3 port. Whilst the hot water is selected check what voltage you are getting on the white wire. Nath
  3. bellairaphon

    S plan

    Link in the boiler?
  4. bellairaphon

    S plan plus wiring for 2 zone programmer

    I would sack the wiring centre and get yourself a wall mounted double box with a blank fascia. Then get a strip of 16 amp block connectors you'll find it a hell off a lot easier to get all your wires into the terminals. And as stated each valve as a perm live ( grey ) the ch on from the clock...
  5. bellairaphon

    Wiring a drayton rf thermostat

    You need to put a link between Live and common. Nath
  6. bellairaphon

    Mains flushing central heating pipework only

    Easier with 2 people. You will need a long hose running outside. Turn the the water off. Drain the heating, remove rads and fit new valve bodies on the storks.then you will depending on set up s plan y plan you will need to remove the motorised valve. Cap the hw curcuit and cylinder return. Now...
  7. bellairaphon

    Sentinel X800 overnight?

    It's a copper HE on the Standard efficiency. It's just coated. Why do you think it's needs doing? Nath
  8. bellairaphon

    Vaillant Ecotec Pro 28 / s30 code. No heating

    Are you getting a voltage from terminal 3? Does your temp dial adjust the temp on the display? Have you tried putting a link between terminal 3/4 Nath
  9. bellairaphon

    How to re-fill a boiler/losing pressure (was gurgling rads)

    Also check your radiator valves have not developed a leak. If you had an open vented system the leak may be on the pipework. But you should call your installer back.
  10. bellairaphon

    How to re-fill a boiler/losing pressure (was gurgling rads)

    Ok take the caps off. Attach the hose. Then open the valve with a flathead screwdriver. Then open the tap before the valve till the pressure rises to 1.5 when the boiler pump is not spin. Then turn the tap off and close the penny valve. Nath
  11. bellairaphon

    How to re-fill a boiler/losing pressure (was gurgling rads)

    You will have a couple of valves possibly with a silver braided hose connected if not they should be capped. They will be either around your boiler or possibly in the cylinder cupboard. If they are remote to the boiler have someone watching the display while you open the valves to fill the...
  12. bellairaphon

    How to re-fill a boiler/losing pressure (was gurgling rads)

    When you bled the rad, did you refill your boiler? The gushing could be the lock shield that's been closed down abit to much. Also the grumbling could be a blocked condensate. Nath
  13. bellairaphon

    Ideal isar HE30 manual.

    http://idealheating.com/downloads/manuals/203319_inst.pdf
  14. bellairaphon

    Vaillant eco tec pro 28

    Press the top left and right button together. Then the top right button. Then it will ask for a code. It's 17, push the top right when you have entered it. Now press the + button till it says d0 what number does it say underneath? Nath
  15. bellairaphon

    Valliant ecoplus 824 not responding

    Test that your getting 240v on terminal 4 on the curcuit board. Then if you are check the divertor valve is getting a 24vdc on the brown and black wire spike when heating is selected. If not then I'd be looking at a board fault. Nath
  16. bellairaphon

    Valliant ecoplus 824 not responding

    Do you have a multimeter?
  17. bellairaphon

    Valliant ecoplus 824 not responding

    So your getting 240v into terminal 4?
  18. bellairaphon

    Valliant ecoplus 824 not responding

    What's the heating temperature set to? Is there an umberella symbol on the display. Nath