  1. S

    Hotpoint First Edition 1200 Spin Advice please?

    wow! that sounds fantastic, little confusing to follow the sequence i will have to read it few times so it sinks in, does this mean it will work on hot water inlet as well and run at 1200 spin? p.s did you miss anything here" Turn dial to a both should flash. Press start" Thanks vey much!
  2. S

    Hotpoint First Edition 1200 Spin Advice please?

    FEW10P 1000 spin. Thanks
  3. S

    Hotpoint First Edition 1200 Spin Advice please?

    Hi everyone, recently my control board went on my machine model (wma 22p). I have sourced a board from a lower spin machine 1000 spin and used it. unfortunately this machine only had one inlet pipe (cold) whereas mine has cold and hot. my machine is working fine, but i've noticed its...
  4. S

    Ideal Isar 24E issue!

    Thanks for all your help, at the end i ended up changing the thermistor (didnt bother checking) bought it from plumb centre for £25. All seem to be working fine now. Thanks
  5. S

    Ideal Isar 24E issue!

    ok i have the manual i know where dhw thermistor is, on the manual its says check this- if the values are incorrect then replace it otherwise its a pcb? "Check resistance using a suitable multimeter connected across the thermistor’s terminal pins At 25 oC expect 9,700 - 10,300 Ohms At 60...
  6. S

    Ideal Isar 24E issue!

    Hi Pontered, please can you advise where dhw thermistor is (is there a way to bypass this). I have check and cleaned out the condensate trap. I still get an error >burner light for 2 sec > followed by 7 > and then H 3 Thanks
  7. S

    Ideal Isar 24E issue!

    Thanks pontered, i will clean out the condensate trap, can you tell me where the dhw thermistor is located if possible (a picture would help) and is this something that could be fixed or do i need a new, if so, can i pick this up from the local plumming shop? Thank you for all your help...
  8. S

    Ideal Isar 24E issue!

    Thanks for the reply Garfield, after having checked further ive noticed the error code is L-F and when i reset it, it worked only for DHW but no CH and then it display error H 3, but DHW kind of still works! sorry for the wrong code earlier, but im sure i saw that error first, ah well...
  9. S

    Ideal Isar 24E issue!

    Hi, im new to this forum and like to say hello to everyone! can somone please advise on an error E- L, i have to turn the boiler off from the main 30 secs and back on, it then works for a while. (did this morning have to go back home to check after work if it is still working). when...