  1. D

    Insulation Test Result Help

    Using L+N at 500v. It trips straight away when power is switched on. I never tried L+E etc. On a TT system with a Hager 30ma RCD.
  2. D

    Insulation Test Result Help

    I have a 16a radial circuit with just the one socket at the end. For some reason now it trips the RCD when I switch the mcb on. I have a megger insulation tester which was given to me before a neighbour moved overseas and it was calibrated a month before he left so I know how to use it I...
  3. D

    Wooden Floor Replacement.

    One of the bedrooms upstairs has a huge hole in he chipboard flooring. It has got much bigger from walking on it and only for the carpet, one's foot hasn't went thorugh the ceiling below. I never liked chipboard and was wondering what sort of alternative flooring should I choose instead? I...
  4. D

    3-pin 16a-32a Socket and Cable Query

    Thats a good point. I had thought about a type c mcb but I wasn't sure if it would solve the problem. I will keep that in mind, now you have mentioned it.
  5. D

    3-pin 16a-32a Socket and Cable Query

    Easy, same way it draws too much and trips the 16a mcb for example.
  6. D

    3-pin 16a-32a Socket and Cable Query

    Cheers for that people. The reason for the choice of a 32a circuit was that my old now broken welder had a habbit of tripping the 16a mcb and sometimes before the 13a fuse had blown. Suppose I would be better wait till the welder comes, see what sort of plug is on the welder and fit the...
  7. D

    3-pin 16a-32a Socket and Cable Query

    I am going to install a 3-pin socket to power my new inverter welder which hasn't arrived yet. I noticed that there are 16a and 32a 3-pin sockets available. I think its wise to install the 32a socket on a 32a MCB. Now a guy today told me that if my welder came with a 16a plug, it won't fit...
  8. D

    Inverter Arc Welder

    I am thinking about purchasing a new Inverter welder as my old heavy style one is on its way out. I know very little about these inverter welders so any preference would be great. I understand there are power source issues to consider like the requirements for a 200a inverter. I had thought...
  9. D

    Consumer Unit Enclosure

    Just wondered encase the MTN range offered something to justify the need for a new range even though they look crap compared to the old MT range. I prefer to see on/off instead of 1/0.
  10. D

    Consumer Unit Enclosure

    I have a full box of new MT106's I got about two years ago and I am about to use 3 of them so I was wondering what differences is there between MT and MTN?
  11. D

    Wiring a PTO driven 21Kva 3-Phase Generator

    Just came across this little page. Maybe in Canada but interesting to me anyhow. http://www.omafra.gov.on.ca/english/engineer/facts/00-059.htm
  12. D

    Wiring a PTO driven 21Kva 3-Phase Generator

    The voltage does change on tractor rpm but with a decent tractor, the load used doesn't really alter the rpm unless you are playing with the arc welder when you would hear a change in tractor note. When my father bought this generator, it was part of a huge grant type thing involving our...
  13. D

    Wiring a PTO driven 21Kva 3-Phase Generator

    I hope the pic gives a better understanding of my generator even though it needs a good blowout. We are single phase so the use of 3phase is of no benefit unless I had it wired with single and 3-phase sockets. If I am limited with single phase, what would be the maximum wattage that I could...
  14. D

    Wiring a PTO driven 21Kva 3-Phase Generator

    Many moons ago my father bought a pto driven 21kva 3-phase generator for use on a dairy farm. Anyhow, we had an electrician out to do a job and asked him to wire it if he had time. He quickly stuck a 3 pin socket on it as thats all he had. Anyhow, that has done the job well but at the end...
  15. D

    Supply to loft.

    Sorry to jump in, but I see folk are talking of 16a and 20a radials on 2.5mm. Is there a reason why you would stick with 16a instead of 20a?
  16. D

    electrical shower - Mira Elite 2 works starts and then stops

    Any Mira Elite 2 showers I have seen are 9.8kW if that helps.
  17. D

    Telephone cable connector

    Good to see someone looking to use proper connection boxes rather than crappy chocbloc which many fools use.
  18. D

    Earthing SWA Armour at Point A or B?

    The reason I didn't want to use a galv box was because of no room to put it as various conduit lengths are in the way. I have room to run the 16mm 3-core swa to the cu though but none for the galv box. (top access entry btw) Is it ok to use a piranha locknut like Spark123 mentioned in my...
  19. D

    Earthing SWA Armour at Point A or B?

    I am taking power from and outbuilding Point A to another building Point B. I just wanted to check with you guys if its ok to earth the armour at Point B because I have no room or good spot at Point A to fit a metal box so I was maybe planning to fit the metal box at Point B instead and earth it...
  20. D

    Keyless Chuck or Keyed Chuck for Percussion Drill

    I have ordered a new keyed chuck and key. The key never really seemed to fit the chuck from the day I got it. Its like the key was just a tad small and couldn't catch the teeth of the chuck so hopefully this new chuck and key will do the business.