  1. N

    vaillant turbo max vuw 242 E

    This boiler is more designed for home domestic property's and can provide 8 litres/min with 35 degree c rise use a Weir cup can obtain them from a plumbing shop, and check the flow rate if its spot on and the temps 35 rise from mains inlet temp then boiler is working ok who ever installed it did...
  2. N

    Biasi riva, hot water no CH!

    first things to check is the stats (tho this should give you fault lights if you _ have the logic pcb (big long one ) or the old type 2 pcbs. and check against the book. (CH thermistor is on the left hand side i believe on this boiler ) If they are seated good, check external controls and...
  3. N

    ICOS-HE12 Boiler

    Some of the newer myson valves have heads you can remove either by screws you see them one either side or a clip you release via a button. This will allow the valve to close on the motor head if it does then all you need to do is locate the spindle on the valve body using a light touch with a...
  4. N

    vaillant ecotec 831 making puffing noises

    Without digging out my Vall cd for the manual to me i would look at the condense if its frozen outside, the best way would be to check the condense trap on the boiler depending on the design one side may be full and the other should not its like a sink trap on a sink. If its a bottle check if...
  5. N

    Black Hole Ventilators.

    without looking at the appliance and working out the ventilation requirements a average vent of about 100cm2 is about right. Most vents come with a baffle inside the tube, you could have it placed at high level as long as it can be checked so you dont get a cold breeze on your legs
  6. N

    Temp for condenser boiler

    turn your control up to max all i can say would be to check the manual for your boiler you can find the info on the website and see what temps you should be getting. Could take the trv off one radiator and see if that increases the heat they can do sometimes if they installed a cretin make...
  7. N

    Temp for condenser boiler

    the overide unless its allready on will bring the boiler on for central heating the radiators should get nice and hot. If they are not hot or poor heat, feel the pipes up into the radiators if they are red hot have you got TRV's / check the pressure on the boiler this be the system pressure...
  8. N

    Temp for condenser boiler

    if their is a wireless room stat then check for the reciver it be by the boiler normaly or the controls. Press the overide button this will eliminate the room stat and force the central heating on full. The room stat will control the temps of the radiators it could be possible its hidden...
  9. N

    ICOS-HE12 Boiler

    i work alot on icos boilers, if a stray voltage above 6volts to the appliance wild make it fire up for central heating on earlier types of pcb. I would also check for a stuck control
  10. N

    loud high pitched noise coming from wlx RS60 boiler !

    depends on your system design but the average age of the boiler and wear and tear mid range on the boiler stat is reasonable higher setting could cause the boiler to get hot and become noisy if the heat exchanger is scaled up.
  11. N

    The radiator in my bathroom doesnt work

    Check the radiator for heat on the pipes, if the pipes are hot is their air using a "Rad vent key" open the screw slightly on the side and see if water or air comes out if water does turn it off its full of water and is ok. If you have a combi or a system with a pressure vessel (sealed...
  12. N

    loud high pitched noise coming from wlx RS60 boiler !

    Strange power up the rest of your house except your heating/hw first. If its all silent then go to turn your system on, the front of your boiler the boiler stat turn him off switch the system on and let it run for 10-30mins or so see if it makes the noise if it dont whack the boiler on and...
  13. N

    loud high pitched noise coming from wlx RS60 boiler !

    well only other thing is the gas, check your meter if its going around at a slow speed quite happy and as your pilot is on its ok. if its going like the clappers then you need attention of a engineer. (call transco ) other then that it, do you have neighbours it could be their system if...
  14. N

    please help glow-worm betacom 24c/30c not flaming

    Don't always assume its the boiler design. If the condense runs outside is it lagged or is the pipe bigger then the white pipe if not then its possibly frozen. If it runs inside did he fit a trap on the end before it enters your drains, this is normal on your sink waste. This can cause a...
  15. N

    loud high pitched noise coming from wlx RS60 boiler !

    Do you have a CO detector as brittish gas love selling, or a smoke alarm. I know from experiance a worn out co detector can screach for ages if its a bit of a sod
  16. N

    loud high pitched noise coming from wlx RS60 boiler !

    check to see if its a noise from the water main turn a tap on if it stops plumbers req if not look elsewhere. If at all possible you could eliminate all other electrical sources for the sound by turning your power supply off at the consumer unit or pulling/switching the mcb's off till the...
  17. N

    Bolier doesn't always fire up!

    Yes i am a "RGI" and deal alot on warmfront and "ideal" stuff ill have a look on that i poped on to see what kind of problems people been having and give some advice :) Only problem is the Corg ID no corgi anymore :) someone needs to update board or will the gas safe stuff work? to stop...
  18. N

    loud high pitched noise coming from wlx RS60 boiler !

    If all of your controls are switched off look for your pump its the roundish thing on a pipe normaly red or grey it wilol either say grunfoss or Wilo or something like that with a wire from it. If that is cold and not vibrating then your system is reasonably isolated. It could possibly be...
  19. N

    Boiler pressure

    For info on the air gas mix check the manual i think on the junior books its page 46. twgas could be right but i would personaly advise you get it seen to asap by a engineer to ensure its working correctly if number 1 and 2 are not related to your fault.
  20. N

    Boiler pressure

    First things to check is: Is the filling loop left on (see boiler manual or silver hose or info on that) not alot of chance in that. IF the pressure rises alot and dumps outside this can be 2 things, 1 he removed a stat on the pipework which is causing the boiler to over heat as the boiler...