Search results

  1. T

    MegaFlo Pressure Issue - what should I expect?

    What is the flow like from your other taps? try running 2 taps at once and what is the flow like then?. Are their any filters on the shower inlets, could their be a blockage in the pipe between the shower valve and the shower head, i would check all these before looking to deep. Paul
  2. T

    Bosch washing machine does not want to finish

    Many thanks Zipper new heater and ntc fitted now have a happy wife great advice. regards paul
  3. T

    Bosch washing machine does not want to finish

    Thanks for your reply zipper, I checked heater to find it was open circuit so i removed it, just for curiosity i checked it again only to find I had 25 ohms. It was definitely open circuit when it was in the drum so i can only think their is a dodgy connection inside and with me banging the nut...
  4. T

    Bosch washing machine does not want to finish

    Hi can anyone offer any suggestions we have a bosch washing machine about 5 years old ss1xx 1200 express. Machine goes through wash but when it should finish its just carries on and starts another cycle. This was on a 40degree wash it should have taken 70 mins but was still running after 140...
  5. T

    Viessmann Vitodens 100 Boiler which moans

    could be auto by pass and probably is
  6. T

    Vokera linea 28 CH and hot water problems

    I have come across this fault a few times it will probably be the ignition board . This is the board fixed to the gas valve. regards paul
  7. T

    which fitting?

    Have you got any dead legs on your pipework, as trapped air in a dead leg could cause your problems.
  8. T

    mira sport

    mira told my customer any shower over 5 years old is not worth repairing
  9. T

    MY BOILER IS TAKING THE P**S

    Ian The boiler does not have to come off the wall to change the plate heat exchanger, it is not to difficult to change but if you dont have much experience it could prove to be a nightmare .You could try adding a chemical cleaner to the system but i dont think it would work, but should clean...
  10. T

    MY BOILER IS TAKING THE P**S

    When hot tap is running what is the display reading ? also run the hot tap near the boiler and as soon as the burner shuts down close the hot tap quickly and read the display , The difference between the two readings should be about 20 degrees if it alot more than 20 it is deffinately a blocked...
  11. T

    veturi shower

    Hi i have fitted two trevi boosts recently they work great . You have to get a 22mm hot supply to shower which has to be the first tee from the cylinder this could be difficult in some houses but if you can go for it regards paul
  12. T

    NEW KITCHEN SINK & TAPS = REDUCED HOT WATER FLOW

    How high is the cold water tank above the hot tap that is giving a poor flow ? You could contact the manufacturer with this measurement and ask them will this tap work with this head of water. I would say that the majority of modern taps with ceramic discs do restrict the flow of water ...
  13. T

    NEW KITCHEN SINK & TAPS = REDUCED HOT WATER FLOW

    If you have not allready done, check that the flexi to the hot tap is has no sharp bend or kink in it , flexis very easy kink and restrict the water
  14. T

    Vauxhall Vivaro van crazy indicators

    Hi all I have a problem with nearside indicator switching itself on when it feels like it. Its very anoying and dangerous when it comes on no matter what i do with the stalk it wont switch off , the only thing i can do is switch the hazards on it still wont stop but it gives me a bit of...
  15. T

    Please help a plumbing novice with a noise issue!

    The economy 7 would go off a lot earlier than the time stated . Try turning the water off when the noise is present if it stops change the ball valve
  16. T

    Vaillant Ecotec Plus. unsure if error is user fixable......

    HI This boiler has a built-in filling loop , if you look up underneath the boiler you will see two grey taps. Look at the position they are in before you start, then turn both taps a quarter turn. You should hear water running and the gauge will go up. The needle on the gauge should be in...
  17. T

    Weird! Brand new bottle trap won't drain!

    Might be worth trying a different trap, I would get an anti-vacuum extendable bottle trap not a big job to swap it over. I think it will solve your problem. The air admittance valve on the trap should allow the water to flow freely. I had a similar problem which I put down to there being no...
  18. T

    Jaguar CH Boiler Weird Noise/Vibration

    Have you got any thermostatic rad valves if so it is worth checking the noise is not coming from one of them . when the noise starts go around turning them off one by one see if the noise stops good luck
  19. T

    volkswagon polo 1982 ignition barrel

    Thanks lads for your help will try to get more info from haynes as suggested . regards paul
  20. T

    volkswagon polo 1982 ignition barrel

    Hi I have an old but good polo 1982 some bast*** tried to steal it , they have ruined the ignition barrel snapped something inside it . I have got a new barrel but cant see how to remove the damaged one , any help greatly appreciated regards paul