Search results

  1. C

    ideal classic RS250 kettling

    p.s. I fitted the insulation myself as he didn't fit any. ive since found out he was supposed to have done this under G3. when I told the young guy he sent to sort the boiler connections, he said it probably wasn't done as its in an airing cupboard so doesn't get cold :roll: . ive just...
  2. C

    ideal classic RS250 kettling

    I asked about the benchmark, after a plumber at work mentioned it, he came round filled out the sheet that came with the cylinder manual, said he would send it off to RM and I would get a guarantee cert through the post. ive now had the Gas Safe cert through for the unvented. god knows what he...
  3. C

    ideal classic RS250 kettling

    it would seem that the vent t's first then the cold feed from the header tank. the second t is behind the expansion vessel.
  4. C

    ideal classic RS250 kettling

    he probably wont some back to correct it. he'll just think im being an enormous pain in the ass.
  5. C

    ideal classic RS250 kettling

    could the heat exchanger have been knackered by running the system reversed for about 3 weeks, probably with about a third of the water being replaced with air every time the pump came on?
  6. C

    ideal classic RS250 kettling

    still kettling, but now its whistling.
  7. C

    ideal classic RS250 kettling

    original pipe work after they moved the pump and cocked up the flow/return: unvented setup: reworked boiler pipework so its the right way round:
  8. C

    ideal classic RS250 kettling

    thanks for the quick reply. I did drain off a small amount after refilling the system just below the pump in the upstairs cupboard. then I poured in the x100 and x200, topped up, then ran just the HW circuit for a couple of hours before using the heating.
  9. C

    ideal classic RS250 kettling

    just scale I would think, as the system heated up well once they connected the boiler correctly. plus when I first drained some water off, to add the x800, it wasn't that bad, just a bit grey/black no sludge. I thought the x100 and x200 were supposed to be good, they have rave reviews. I...
  10. C

    ideal classic RS250 kettling

    ok had a new unvented tank fitted and system changed from gravity to fully pumped. initially the plumber connected to the original gravity connections on the boiler and got the flow and return the wrong way resulting in trapped air, probably in the heat exchanger, see this thread...
  11. C

    air trapped in boiler circuit

    p.s. there's no restriction on the cylinder coil return, should there be? as I would have thought the water when the hw is calling and ch will just rush round the hw coil.
  12. C

    air trapped in boiler circuit

    picture of tank and stuff: please tell me if there are any other Fups, as ill take him to task when hes sorting the other mess. also I didn't realise unvernted was supposed to be lagged by the plumber, he didn't, but I did it before I found out he should have done it.
  13. C

    air trapped in boiler circuit

    last night I went through the manual to check the connections. the plumber, who is gas safe, I call him a plumber but im beginning to wonder, has connected to the boiler back to front. so the flow is going down across the heat exchanger. probably the air is getting forced into the heat exchanger...
  14. C

    air trapped in boiler circuit

    ive had an old pumped CH gravity HW system changed to an unvented indirect fully pumped, using the gravity 28's for a flow and return. they moved the pump from above the boiler and put it in the cupboard upstairs where the cylinder is. the ch and indirect coil are still header tank fed. the...
  15. C

    leds glowing with light switch off. varilight eclique dimmer

    well after some weeks varilight sent me 2 new dimmers running the latest firmware. the result so far is they don't come on randomly when remote programmed, but the 3 remotes ive tried don't work either. the switch responds during programming and that's it, after that the switch doesn't respond...
  16. C

    leds glowing with light switch off. varilight eclique dimmer

    nope removing the eop's didn't help. so basically varilight touch dimmers seem to have a problem even on a basic 2x 18W setup.
  17. C

    cheapest to buy and run water softener

    a plumber on another site said he fitted Monarch. do they do a metered regen or timed.
  18. C

    cheapest to buy and run water softener

    wondering what would be the cheapest water softener to buy and run? its for a 4 bed house with one bathroom, maybe shower room later. 3 people, one who is mad and uses water like its unlimited. we had water bills about 5 years ago approaching £600 a year, when my son was a baby. he has eczema...
  19. C

    leds glowing with light switch off. varilight eclique dimmer

    just wondered if the weird problems could be caused by some Ethernet over mains adapters that ive got? I have 2 that were in an old BT vision set.
  20. C

    leds glowing with light switch off. varilight eclique dimmer

    got up this morning to find the 2x 18w halogens on. not sure when they came on, maybe when I used the electric shower? checked the light wiring some time back and it appears to have been totally rewired, new colours.