  1. R

    Cap the gas point?

    maybe a hammer might help :)
  2. R

    Kettling noise in boiler

    Could do it yourself but like you said you have no idea, get it wrong and you could end up with a nasty bill. Get someone to come and have a look first and ask for quote to sort problems.
  3. R

    Sink waste snaffled! Help!

    Go to any plumbers merchant, ask for a standard kitchen waste kit and a u trap. or pick up the mcalpine catalogue any good merchant will have it, its got loads of waste bits to pick from. or call a plumber if its standard it will only take about half hour to sort, if not they will soon let...
  4. R

    Cap the gas point?

    Cooker bayonets are only a temporary disconnection point and if you permantly remove the cooker it must be capped.
  5. R

    I THINK I DID IT RIGHT.

    expansion vessel precharge pressure should be in the manual but some where between 1 to 2 bar should be a safe bet , its is always best to find out the correct pressure,try ringing the manufacturer they shold tell you
  6. R

    air lock ?

    simple anwser is yes it would work as long as the pipe work is not blocked in some way , why not just try attaching a hose to any drain point but be careful dont want a flood , or try turning off all the other rads running the system to get out any air stuck in the pipework out. (watch out if...
  7. R

    I THINK I DID IT RIGHT.

    try to drain the boiler without using the prv there is a good chance it may not reseal after, there should be a point to drain your boiler without using the prv. or else get a prv just in case.
  8. R

    Myson Apollo 15/30 B - again....

    thermocouple on these boilers have an interrupter connected to an overheat stat on the top of the heat exchanger, if the boiler is overheating it will shut down , poss faulty stat, blocked heat exchanger (inside pipe work and external fins ) , blocked flue , my fav would be intrenal blocked heat...
  9. R

    How to connect a wall hung WC to a remote cistern

    most wc pans and cistern connect using 32mm or 40mm upvc pipes, standard waste pipe normaly works.
  10. R

    air bricks below dpc

    Thanks for the info gents. guess who is not getting paid till the ducts are in. :x
  11. R

    air bricks below dpc

    I have air bricks to the front and rear of my property just below the level of the dpc, at the front they are in a solid wall , at the back i have one each end of a sliding double glazed exterior wood door approx 2.5 mtrs wide, the floors of the house appear solid with 1" chipboard laid in some...
  12. R

    condensing boilers are useless

    what is the point of a regular boiler that the flow tempratue can be set to 50 degrees c when its used to heat a hot water tank :?: (not much point in having an interlock)
  13. R

    changing mixer shower to Power shower

    The reason for separate feeds or first feed is to stop variation in water temp when other taps or draw offs are used,so you could use the existing pipes and it could work fine,but it might cause temp/mixing problems. also would invalidate warranty if not installed to makers instructions.
  14. R

    air in 1 rad

    sounds like the open vent pipework, it must rise continuously and be at least 22 mm pipe,might have been mucked up in the move.
  15. R

    no hot water

    Try contacting these people, Gledhill Building Products Limited Unit 4, Sycamore Estate, Squires Gate, Blackpool FY4 3RL Tel: (01253 ) 474550
  16. R

    Steel or Acrylic Bath

    Your selling it ! get the best looking and cheapest you can find and use that, it all boils down to looks in the end. Who has a bath or shower when then they look to buy a place
  17. R

    Central Heating Breakdown Cover

    Or take the fifteen pounds a month save it 10 years do your acs get corgi reg, and do it yourself :)
  18. R

    Connecting a mixer shower unit

    try using p.t.f.e tape to pack the threads out
  19. R

    Sime combi boiler

    try pushing in what looks like an on off switch should spark then light the pilot (if its the right model but you havent stated which sime)