Search results

  1. A

    Does PVA go off..

    The finish he achieved on all the walls in the end was very good, he was spraying them down a lot more than he usually would, and it took a lot longer too, the reason for the initial question as to the quality of old PVA. So he is back in the other room today. Might be an extra day to...
  2. A

    Does PVA go off..

    I supplied all the materials bought from wickes the day before he started.. All bags were date checked, good until November according to the bag. I've had him to do jobs before for me and other family members too and was more than impressed with the results previously. The walls were...
  3. A

    Does PVA go off..

    Had a plasterer in who's had no end of grief, with his plaster drying out too quick. I had some PVA left over for last time I had plastering done (24 months), and bonded all the walls with this. Does PVA have a shelf life, there's a lot of crazing going on, with cracks as soon as the plaster...
  4. A

    Radial to Ring and other questions..

    Both the 32A ring final and 32A (2x radial circuits) are protected by an RCD as well as Shower and immersion heater. In Coventry so don't have a the Tamworth issue (sounds interesting..) I've not got proper testing gear admittedly but determined it was 2 radials by. 1.Checking for...
  5. A

    Radial to Ring and other questions..

    By this I meant more the fact I don't have considerations to take into account during decorating I realise this is notifiable. Would the sparky putting the new breaker in have to check all existing cables in the radials first? These are the reasons why I'm asking the questions now as I am...
  6. A

    Radial to Ring and other questions..

    I can do the work, having done lots of electrical work previously within the regs, and before regs were passed. What I can't do is test with certified gear but confirm continuity with a multimeter, and ensure all connections are made correctly. Cost wise I would have thought it would be a...
  7. A

    Radial to Ring and other questions..

    Hi, I've recently moved into a new property and have a couple of questions for you guys. At present their are 2 x 32a breakers in my CU. plus others for other circuits. One is serving the kitchen plus a few other sockets on 2.5mm cable, this is a ring. The other is feeding 2 radial...
  8. A

    Worcester Bosch 24i Greenstar - Not firing

    At this point thats my thoughts as its a fault finding mission. Cheers
  9. A

    Worcester Bosch 24i Greenstar - Not firing

    Hey. I've looked through various posts at for this boiler to try and find what might be wrong with girlfriends boiler. Its not providing HW or CH, and the blue light flashes quickly which the manual suggests is temp sensor/fan maybe. Yesterday I cleared the siphon tank which was...
  10. A

    Cooker & Hob Switches

    Currently refitting my kitchen which requires a bit of rewiring in the process. I plan to get a 13A single oven, and gas hob. As the cooker is only 13A can it just be spurred off the 30A ring main for the kitchen to a cooker switch, and the gas hob to a 3A FCU? Is it best to spur them or...
Back
Top