  1. C

    Geewizz...........

    never seen anything like that before, although i have seen one explode when it decided to die.....
  2. C

    power cuts

    dont need that much power lol, just love to be able to play with a genny that size :lol:
  3. C

    power cuts

    on average we get one a month, and they usually last for about an hour, although somtimes they can last up to 3 hours or so. Just got to find the money for a massive 3 phase, 250KVa diesel back up generator...............
  4. C

    Landing switches

    try playing with the intermediate, one yellow to each L1 and one blue to each L2, i had this problem with one of my intermediate switches
  5. C

    Implications of Part P

    I'd say future proof it and use new colours, be neater
  6. C

    Shed/workshop electrics

    by 18amp i guess you mean 1.5mm2 SWA? This is a wee bit too small for the job idealy. What sort of load will those sockets be supplying? And i presume by security lights you mean 500w halogen lights?......
  7. C

    Old wiring colours - is this English?

    Black = Live Blue = Neutral
  8. C

    Socket under Kitchen Sink?

    we have two sockets under the sink here by a mass of pipework. Its acceptable in the eyes of the regs, just isn't the best way of doing this things. somthings you have to live with!
  9. C

    Running a current through garage door handle?

    I'll probably get shot down for saying somthing like this....oh well Been thinking about this and the most common thing i can think of is electric fences, If somone on the forum wants to say how they work, as i dont know, it might be possible to adapt one. Stick some huge yellow warning...
  10. C

    fluorescent light removal

    thats a long sentance...... dont suppose you could take a photo? they often make these things soo much easier
  11. C

    Rewire Completed

  12. C

    Rewire Completed

    where do the tails before the cut out go?!
  13. C

    replacing an MCB?

    your RCD is only rated at 40amps? and you have a shower or other appliance running on a 45 amp breaker. I would recomend the RCD be changed to a higher rated one.
  14. C

    Odd smell at Consumer Unit

    Does it smell of fish? Check and see if anything is over heating or if therre are any loose connections.
  15. C

    110v CTE transformer

    it doesn't have a trip switch..........
  16. C

    110v CTE transformer

    I have just bought an elderly 110v transformer (CTE). It is rated at 2Kva continuous. My question is how much does this mean i can draw? if i rememeber Kva and watts are not directly related, ie its not a 2Kw transformer. What rating of fuse would you recomend i use in the primary side? thanx
  17. C

    the MK split load cu (screwfix!! £79-99)

    lol, try living here, full 21way MK CU plus another one with 2 ways used......and i need to add more circuits! you really can't put enough spare ways in!
  18. C

    Ring mains!

    Well its a brand new house, so it really shouldn't have problems like this in the first place. Another thing to go into the "snagging" list. lol just a thought, would this also mean the voltage drop would be too high on this circuit?
  19. C

    Ring mains!

    hey, i did some more measuring! The house works out at about 140m2 including kitchen, although this is on a seperate circuit. although the upstairs floor is larger, as it goes over the garage.
  20. C

    Ring mains!

    Hi there, i was doing some measuring today, and it struck me. How big is the area a ring main can serve? my believe was that it is 100m2 but when i was mesauring today i noticed the ground floor of my house is larger than 100m2!