  1. J

    stiff pump head

    I have drained the primary circuit, removed the electrical connections, plus the 4 allen screws but cannot shift the pump head. it seems stuck! Any tips. I have tried crack iot release spray, a drop of oil but the pump head remains stubborn!! it's in a worcester cdi! :cry:
  2. J

    Worcester 24cdi RSF divert valve/replacing question

    cheers for your help mate. This is definetely the trickest boiler/part I have had trouble with ! I did get the clip back in, but then the bypass tube wouldn't get in the correct position again and got caught on the DHE thermistor! So i removed that and now am having a break before getting...
  3. J

    Worcester 24cdi RSF divert valve/replacing question

    Hi, I hope someone can help me please!..... I have just replaced the diaphragm in the diverter valve, and to do this I had to remove the plate heat exhcnager, and filling loop assmebly. All was done quite quickly, but on replacing, I am struggling to connect the bypass tube into the plastic...
  4. J

    Intermittent central heating problem

    you'd be better off with a nice new Honeywell wireless room stat ideally with a new boiler like that, but as said don't touch and get installer back. It could be a dodfy relay in the timer even. You could try measuring (with power to system off) continuity between the contacts when the...
  5. J

    issue with gloworm micron 70ff

    I was thinking that from the start, but you will need a gas engineer to come and purge it for you and to check it's gas tight after. I've had a few before when pilots been turned out and after being re-lit a week or so after, the air has caused it to not light immediately, so again the...
  6. J

    Hot Water problems

    do you have 2 of those valves or just 1 with 3 pipes from/to it?
  7. J

    screeching boiler

    yeah it can happen, as Agile says though, call your uncle back!
  8. J

    screeching boiler

    could be air trapped - might need slackening to remove but get ypour uncle back to take a look
  9. J

    screeching boiler

    the diaphragm is a part in the diverter valve that allows hot water to fire the boiler up eg when a hot tap is opened. i'm not saying it is this for sure. can you open the hot tap etc and when the noise begins single out where it's comign from?
  10. J

    screeching boiler

    sounds like it could be coming from the diverter valve - when it moves inside and changing ports
  11. J

    screeching boiler

    can you listen and hear where the screech is comign from? could be air trapped possibly when the diaphragm was replaced
  12. J

    issue with gloworm micron 70ff

    is the gas meter definetely working ok? is there a reset button on the meter? might need to call the gas board up to check. trying turning power off at the spur feeding the boiler and back on again or check the fuse in it
  13. J

    Worcester Bosch 28i Junior: hot water but no central heating

    I've heard of a few of these faults before. I find the best way to fault find this is by opening a hot tap and seeing if the combi still fires instead of going out so soon.
  14. J

    Boiler breakdown Baxi courses

    I have been on manufacturer courses, they teach you a bit about their diagnostics etc but don't get much into fault finding with boilers generally. The worcester course was decent, gave me a free card to help with fault finding, plus a long reach magnetic pump head / gas valve adjustment key...
  15. J

    Boiler breakdown Baxi courses

    have you heard about gastec training in Milton keynes? it is 2 days and basic and adavanced apparantly.
  16. J

    Boiler breakdown Baxi courses

    thanks for your reply, much appreciated. that sounds interesting. I have used a mutlimeter to test components such as fans, air pressure switches, thermistors, gas valve solenoids, pumps, overheat stats, low water pressure switches, etc both dead and live. i just wondered if the course...
  17. J

    Boiler breakdown Baxi courses

    thanks for replying. I have just looked, but wondered what problems it covered, basic or more advanced ones and how in depth it went.
  18. J

    Boiler breakdown Baxi courses

    Hi Those of you who have attended or heard reviews about the Baxi boiler breakdown/fault finding courses, please could you share with me briefly what the courses actually cover? I have heard good reviews about it, and would like to attend, but have also heard from 2 engineers that it is...
  19. J

    Combi boiler diverter valve q!

    Usually the motor only becomes activated when a hot water demand is made, by the flow switch. then the valve body inside via the motor moves and closes the heating port.
  20. J

    Descaling heat exchanger plate on an Ideal Response Combi

    very interesting, thanks for that advice. I suppose it's cheaper than replacing and worth trying