Search results

  1. E

    Painting my newly plastered kitchen...

    Noted on the Rich Matt - will be getting some Trade Supermatt for the mist coat on the walls then! Had a look the other day on the Dulux Trade website but it seems that they don't do a Non-vinyl matt in the colour the mrs wants (69BG 77/076 Holiday Blues 6). It seems that Supermatt and Fast...
  2. E

    Painting my newly plastered kitchen...

    I'm having the kitchen done at the moment and have had the walls and ceiling plastered (walls bonding coat and skim, ceiling plasterboard and skim). I've painted the ceiling with a mist coat of Dulux Retail Rich Matt, because my mrs was in a rush and wanted it done yesterday and I'm going to...
  3. E

    Bathroom ventilation problem

    Ok, bearing in mind that one tile needs changing and it is easily within arm's reach of a person standing on a ladder working out of the velux window - would this vent tile do the job? http://www.klober.co.uk/product3.php?id=72 Any ideas as to a fair price for the job? I've had a few...
  4. E

    Bathroom ventilation problem

    Hi, I have a sloping internal roof in my shower room with a Velux window and an extractor fan with a delay fitted to the lighting circuit but I have still been having problems with damp in the room. I removed the extractor fan from the sloping ceiling as it was rattling a treat and replaced...
  5. E

    Carpet Gripper Rod

    The carpet fitters are coming on Monday, I refuse to pay £1.80 per metre as Allied quoted for gripper rod, I've found gripperrod for wooden floors on tradepriced.com at reasonable prices but it probably won't get here in time. Does anyone know where I can get similar spec gripper rod around the...
  6. E

    Decking Framework

    I've just dug out a small strip (5.7m x 1m) out the back of my house for decking. I was going to use 5x2 for the frame, currently I'm planning to put supporting blocks every 1.5m or so - sound about right? Due to a drainage pipe running under the planned deck placing supports to the central...
  7. E

    New 1/4 landing

    I'm looking to put in a new 1/4 landing so I don't have to keep going down and then up the same steps all the time. I'm not sure the 2 steps are level, is the best way to approach this to put a piece of something like 18mm ply onto the existing steps, level using wedges then screw in place...
  8. Untitled

    Untitled

  9. E

    3 way switching

    Thanks for that, spotted the neutral thing too - I'm a numpty. I'm not really in the mood for running more cable so I'll go and have a look at the MK grid stuff. Thanks again.
  10. E

    3 way switching

    Hi all, Just a quick, is this possible question. I currently have 3 way switching to my landing light, from the hall downstairs, the landing at one end and the landing at the other end. The intermediate switch is a 2 gang modular crabtree switch that looks rubbish - I have MK Logic Plus...
  11. Untitled

    Untitled

  12. House

    House

    Random pictures and diagrams
  13. E

    New boiler - 22mm gas supply

    Not the most successful weekend so far - I whipped the DHW heat ex out on Saturday, not that bad at all (I gave it a quick rinse through and got rid of the scale and sludge using domestic descaler) then I fitted a new towel radiator and flushed the system through a couple of times, water was...
  14. E

    Which descaler ?

    There must be something that does an ok job? I don't really want to spend over £120 on a new one when I could clean the one I have. Similar to above - do you have to buy the whole Heat Exchanger seal kit or is there a DHW HEX Seal Kit of its own? Thanks!
  15. E

    New boiler - 22mm gas supply

    I've found a website selling the kits mentioned above and I'm going to order them, just a quick sanity check though, to recon the diverter vlv, clean the heat exchanger and recon the DHW flow vlv (while I've got it off anyway) will the following kits do? Seal Kit 760 Repair 3 Port Vlv (Pt No...
  16. E

    New boiler - 22mm gas supply

    Sorry should have added that the Hot Water has been fine in the past (although this is the first winter we've lived in the house), which leads me to think that it is a component failure issue that seems to be getting a bit worse.
  17. E

    New boiler - 22mm gas supply

    Thanks - sounds like something I can get on with. Can you suggest anywhere reasonable to get hold of the diverter recon kit (or a baxi diverter as you suggest)? I suppose the plate exchanger is just a case of remove and clean with industrial descaler? I'll check the heating return filter...
  18. E

    New boiler - 22mm gas supply

    Just an update - got fed up waiting for the recommended Heating Engineer so I called Alpha. They gave me the name of the local contractors, they came round 3 days later, serviced the boiler and now it sort of works. Engineer said that it probably needs a new diverter valve and dhw heat...
  19. E

    New boiler - 22mm gas supply

    Nope, got a heating engineer recommended to me. The Alpha helpline said DHW temp sensor or PCB - sounds like they're trying to sell parts! The boiler was used for house before it was extended - 1 bedroom and ensuite added plus new lounge, boiler was then re-sited. I'll try and speak to...
  20. E

    New boiler - 22mm gas supply

    Intermittent DHW and CH, I think we're going to be in the house for at least 4 years so don't want to chuck good money after bad to get this thing sorted. I think the APS is the problem with the Alpha at the moment so going to try that before doing the new boiler option (with associated...
Back
Top