Search results

  1. J

    RE: BOILER PRESSURE PROBLEM - PLEASE HELP!!!

    I thought a holed plate heat exchanger would make the system pressure rise to approx 3 bar and the prv to open?
  2. J

    Potterton Suprima 60L keeps turning off with Green Flashing

    some boilers overheat when on maximum, the potterton profile is a common cause of this - I know it;s designed to but it just doesn't - like isolation valves under the boiler are designed to be used to change a part without draining down whole system etc - but we know these are not always...
  3. J

    Potterton Suprima 60L keeps turning off with Green Flashing

    sometimes instead of locking out some boilers just cycle on and off the boiler stat if air was in the system/circulation problem then that would also cause overheat and lock out if that was the case
  4. J

    Potterton Suprima 60L keeps turning off with Green Flashing

    try turning the boiler stat down a bit and see what happens - if set too high or to max they sometimes cause the boiler to overheat
  5. J

    Ravenheat CSI 85 - No HW & temperamental Central heating

    Is there power going to the pump when hot water is selected? sounds like a pcb fault when ch works intermittently, what exactly happens - is there a pattern to it or is it random?
  6. J

    Potterton Suprima 60L keeps turning off with Green Flashing

    is the pump rotor free? you need to check the resistance of thw windings and also see if the impeller is ok.
  7. J

    Ravenheat CSI 85 - No HW & temperamental Central heating

    so no hot water ? how does the room stat work then if there's no timer... what powers the room stat?
  8. J

    Boiler PRV change question

    sorry there's only 1 open end connected to the primary system - so the vacuum holds then.... :)
  9. J

    greenstar 28i junior stopped

    does the hot water work? what's the pressure on the gauge? how fast does the blue light flash?
  10. J

    Potterton Suprima 60L keeps turning off with Green Flashing

    sorry APS- air pressure switch have you tested the pump? when you say it's running it doesn't mean it is working correctly Also the fan - have you tested that? Byt fan and aps are gas related and you need a gas safe enginerr to test them
  11. J

    Potterton Suprima 60L keeps turning off with Green Flashing

    PCBs are often faulty on these - also check the fan's running at speed and the APS
  12. J

    Ravenheat CSI 85 - No HW & temperamental Central heating

    if the fuse keeps blowing / rcd trippig Id check pump and fan first, then possibly gas valve as use 240volts
  13. J

    Boiler PRV change question

    know about the vacuum, but there'll be 2 open ends, not just 1 and we all know that sometimes vaccum's don't hold !
  14. J

    Cold Radiator After Removing One To Decorate

    try bleeding the highest level rads - any water coming out of them? could be a blocked cold feed. or some air in the system somewhere - try turning the trv/manual valve not lockshield off on all hot rads and leave the cold one trv open
  15. J

    Boiler PRV change question

    Thanks for your reply - yep good point about drainibg through the prv - but drain the whole system water?
  16. J

    Boiler PRV change question

    Just a quickie - what would you recommened the best way/quickest and easiest way to replace a PRV in a combi boiler - as turning off the isolation valves often results in a leak. Is it best to drain the system pipework ?
  17. J

    Pumpintermittent fault when hot question...

    I just wondered why this happens - what causes the pump to slow/fail when hot only?
  18. J

    Pumpintermittent fault when hot question...

    Hi I've heard that an intermittent fault that can occur on a combi / boiler is that a pump can fail when hot - so when tested (cooled down) you can't find the fault! Is this true.... ? If so, how do you find this fault out :)
  19. J

    Ravenheat silver star ls100 combi problem

    to the original poster: what CLICKS do you hear when the boiler starts up? Ignition sparking clicks? Sounds like a board fault if there's no power to the fan or pressure switch as mentioned. To: Slugbabydotcom/STevenJames125 or others: If the PCB RELAY was faulty - how would you...
  20. J

    Potterton Performa Fault Follow-Up. This Is What Was Wrong

    how comes the air pressure switch was fine in hw mode but in heating ti kept tripping? very strange!....?