    Vaillant AquaPlus 362-7 & Hive Heating

    Brilliant thanks @CBW will get it sorted and installed then
  2. A

    Vaillant AquaPlus 362-7 & Hive Heating

    This is my control panel which is set to "sun" all the time, timer is essentially disabled on boiler side. @CBW
  3. A

    Vaillant AquaPlus 362-7 & Hive Heating

    Honeywell thermostat wiring, it's down in hallway right near front door with no rad nearby, hence why I want hive as the rest of the house gets red hot lol I can pull it away from wall in bit if you need to see anything behind
  4. A

    Vaillant AquaPlus 362-7 & Hive Heating

    Below is wiring on boiler side. @CBW will grab a pic now
  5. A

    Vaillant AquaPlus 362-7 & Hive Heating

    Hi all, I have a Valliant Aquaplus 362-7 and looking at installing Hive Heating. The current layout is a manual programmer in the boiler fascia, and then a wired thermostat down in my hallway. Water is on demand, no tank, so I only need the Heating version of the Hive, and single channel...
  6. A

    Vaillant AquaPlus 362-7 Tripping RCD

    Sweet will try your disconnect first. When does the diverter valve or sensors start to come into play? Take it if the pumps nailed it'll be that causing an Amp draw and pop the RCD
  7. A

    Vaillant AquaPlus 362-7 Tripping RCD

    Ok will give it a go in a mo, I know the boiler sits ON no problem at all until there is a demand for HW or CH. Is the pump not the first thing to kick in when I put demand on?
  8. A

    Vaillant AquaPlus 362-7 Tripping RCD

    Rough layout inside
  9. A

    Vaillant AquaPlus 362-7 Tripping RCD

    Checked pump thru access screw and turns freely...
  10. A

    Vaillant AquaPlus 362-7 Tripping RCD

    If i need to isolate the pump & boiler where is best on the pipework in images to do this? ideally i want minimal water loss from the system overall, i'll kill the cold feed into the property, and i'll look the water in the storage tank within the boiler, but ideally don't want to lose all...
  11. A

    Vaillant AquaPlus 362-7 Tripping RCD

    Summary : when boiler fires to give HW or CH it trips RCD. Backstory: > RCD within electric box contains 2xsockets (ground floor, first/second floor), 2xshower (first floor, second floor) + main switch. > Main switch is tripping when boiler fires, but as expecting tripping all sockets and...
  12. A

    Valliant AquaPlus VUI 362-7 F24 Error

    All valves open, tank charged etc. I can only think its the pump
  13. A

    Valliant AquaPlus VUI 362-7 F24 Error

    Screenshot 2022-04-26 123040 by ADurr posted 26 Apr 2022 at 12:31 PM Manual error code, pretty much points at the pump either being shagged or blocked.
  14. Screenshot 2022-04-26 123040

    Screenshot 2022-04-26 123040

  15. A

    Valliant AquaPlus VUI 362-7 F24 Error

    Hi all, I've got a Aquaplus VUI 362-7 and seem to be getting a repeating F24 error, which means heating is stop/start and also i don't seem to get HW on demand, only the quantity pre-heated in the storage tank then it runs cold. F24 from searching appears to be a multiple list of things to...
  16. A

    Combi boiler hot water shut off to tap

    Hi guys got a aquaplus valliant combi boiler and need to stick some isolating valves on both hot and cold tap feeds in kitchen (boiler is on middle floor). which valve can I isolate the boiler with so that there is minimal hot water loss from the system whilst I do the isolating valves...