    When did earth sleeving become the norm?

    it was definitely on a monday don't know the exact date though
  2. it's not that hard

    Thermostatic shower question.

    inside a thermostatic shower is a coil that adjusts immediately, if someone opens a cold tap the coil automatically adjusts so you don't get scolded and vice versa
  3. it's not that hard

    A Filling Loop Story...

    If it's just the shut off valve just turn off the cold water mains and replace it, when you undo the braided hose from the shut valve there shouldn't be any water coming from the heating system,you can always reconnect if the check valve isn't holding,
  4. it's not that hard

    Fitting a Yale type lock to a uPVC door with Eurolock

    Get a eurolock with a turn knob for the inside and key outside
  5. it's not that hard

    Accessing inside of a mixer tap

    to remove the handles unscrew the smaller vertical arms then the chrome body should pull off but maybe a cap on the ends you take off and unscrew, no there are different sizes, take the caps to a shop and ask if they have the same sized spindle that the handles will fit on, good luck
  6. it's not that hard

    Undersink water filter

    You can get RO filters in different sizes,the good thing about RO is I think is the only filter available which gets rid of flouride, which is a poison, the only two countries in the world that add flouride is America and here, makes you wonder !!!!!!!!!!!!
  7. it's not that hard

    Looking to replace double panel radiators

    I gave up central heating some 20 years ago,but remember about 30 years ago when radiators with fins first came out,asking then what were the fins for I was told that they distribute the heat around the room better,the fins making the rising heat flow upwards and outwards,whereas the old type...
  8. it's not that hard

    Lukewarm radiator

    I am sure that a plumber will have tried this but just incase, the first thing to try with any radiator not getting hot is to shut off all the other rads,letting the water circulate around this one,it could push any air out, but it's strange that one side is getting warm and not the other...
  9. it's not that hard

    Noisy new bypass radiator !!

    then suggest something or trade yours in for some man sized ones
  10. it's not that hard

    How to plumb incoming mains water

    15mm pipe is adequate,why not think about a new water main,they can be installed by a mole so not disturbing anything inside the house,I have used this method where the water pressure is to low to for a combination boiler but leave the existing main connected,one main to the boiler the other to...
  11. it's not that hard

    Noisy new bypass radiator !!

    could be the valves,fit two bent chrome male iron to coppers and discard the valves.
  12. it's not that hard

    Can someone help me with compliance for a wet table.

    those garden sprayers, where you manually pump them up to get the pressure.
  13. it's not that hard

    Smallest shower room EVER!!!!

    just use it for peeing in,but tell any women using it they will have to drip dry.
  14. it's not that hard

    combining bath and basin waste

    I wouldn't worry about it unless you are a very very hairy family.
  15. it's not that hard

    Radiators always warm

    It's probably the 3 way valve stuck in the mid position or if it's only the upstairs rads getting hot and downstairs they stay cold, then it hasn't been piped up properly and you are getting back circulation.
  16. it's not that hard

    Commercial vs Domestic Washing machines and Dishwashers

    If you had bought a domestic dishwasher and put it in your commercial premises the guarantee would be null and void.
  17. it's not that hard

    leaking drain valve

    yes, if it's exactly the same,unfortunately the threads are different sizes, but you could try changing the washer and making sure there's no grit inside.