Search results

  1. M

    where's my hot water gone?boo hoo baxi 105e

    Baxi manufactered two models of the 105E , their terminology ,105E ,or 105E INSTANT.Although both models are almost identical ,we need to know which model is installed in your property , then someone on this site will be able to give you the correct advice .
  2. M

    potty HE

    I would ensure that the inlet pressure to the gas valve , when the boiler is firing at full rate ,maintains at least 20 mb. If this is so , I would then take G.T.P:S advice .
  3. M

    Boiler Warranty

    As Mr . Agile has stated , compare other companies , besides B.G. ,then the decision is up to you . Normally , a pretty reliable boiler .
  4. M

    potterton puma 80

    Most likely to be a failed wax capsule type diverter valve within your boiler has failed. Other things to check , is the auto air vent operational , not sludged with corrosion.Also ensure pump is operating. This type of boiler , on demand for heating , fires up the burner , pump runs and...
  5. M

    British Gas Homecare

    We are a small independant company,trading for 32 years,with many contract customers.I am an ex BG employee{14 years},also I was an employee of Baxi Potterton,Heateam. I see objectives from both sides of the coin.It is easy to pick the usual suspect on a faulty boiler,when time is crucial, and...
  6. M

    biasa standard combi,biasi condensing combi.

    As previously stated in my last post,thanks again for all of your input.We will accept the :boiler service: part of the contract,breakdowns are priced at normal rates.No other business are prepared to accept these appliances on a comprehensive contract,therefore nor shall we.I will keep you...
  7. M

    biasa standard combi,biasi condensing combi.

    Thanks for your replies, I have been away for the weekend with the family,just returned.My feeling is that we will accept this maintenance contract for these properties,i like a challenge,but on terms which will be financially lucrative for the business.The boiler maintenance is a smaller part...
  8. M

    biasa standard combi,biasi condensing combi.

    This question is directed towards engineers with experience of these boilers.I have only ever been to one,fan failure.The reason for this query ,is that we have been offered maintenance contract on 72 of these units, all under five years old.Answers appreciated.
  9. M

    Vaillant boiler fault code

    Had the same problem recently with a vaillant system boiler,fault was on the auto air vessel,renewed part and now o.k.This may not be causing your fault code,but worth investigating.
  10. M

    Regular lockout on Range Powermax 155

    Potterton now have ownership of the Range Powermax products.Google search for :Baxi Potterton Parts Arena:.Download and print instructions.
  11. M

    New Boiler Recommendations

    Vaillant 831 condensing combi.Two year guarantee,excellent domestic hot water flow rate,extremely reliable.
  12. M

    Noisy Baxi Boiler 105e

    The fault which you describe is almost certainly from the ;o; rings within the diverter valve.The repair which has been carried out by the manufacturer is guaranteed for a period of thirty days.Recall Heat-Team to effect a proper repair.
  13. M

    Biasi s combi boiler

    Sounds like knackered diverter valve.
  14. M

    New Boiler - Warm Water?

    May be that they are not familiar with the Vaillant brand of boiler,and therefore unable to diagnose and effect a correct repair.We install in excess of 250 Vaillant boilers each year.We receive excellent support from the manufacturer and also their field engineers.Anyway back to your original...
  15. M

    Potterton 80 No power

    Have a look on ebay.
  16. M

    Exploding ( very loud *bangs*) Potterton Promax HE Boiler

    Best course of action is,call Heat-Team[ number on baxi website], for a fixed price guaranteed repair.Alternatively arrange a call with British Gas to attend on a fixed price guaranteed repair of your boiler.On this boiler there have been quite a few modifications to the P.C.B.Re,moving fixed...
  17. M

    potterton 80 pressure up and down

    Probably two faults.Boiling fault on hot water ,sticking domestic hot water flow switch.Increase of internal water pressure on c/h. demand,points to defective pressure vessel.Also the auto air valve, fitted top left of heat exchanger,prone to blockage.
  18. M

    Faulty Diverter on Combi??

    From the symptoms you describe,the fault is with the diverter valve motor.This is an easy and inexpensive straight swop.Usually a myson motor,ensure replacement has the same identification number.Google search on :baxi parts arena : for part number.
  19. M

    Potterton Suprima 70: kaput - on New Year's Eve.

    Best advice to you,is have BG. carry out a fixed price repair,renewal of p.c.b . for £130 ,exceptional value.