    Baxi Bahama 100 cuts out after 20 seconds

    Rang joe 90, and he definitely said the problem would be the flow switch.Why is he always right?Must be the N.H.S. specs.
  2. M

    POWERMAX 155

    I f my memory is correct ,there are two pumps within the boiler casing,the one on the left is the heating pump for radiators, and the one on the lower right is for the domestic hot water.This is activated by the flow switch around the blender pipework.Possible faults,failure of domestic hot...
  3. M

    [peugeot 807 HDI

    What would be a reasonable price to advertise this vehicle for sale. 90,000 miles first reg 2003 good condition fsh tax til nov 06.
  4. M

    Baxi Bahama 100 cuts out after 20 seconds

    Download boiler fault finding from,Parts Arena,on Baxi website.Majority of problems on bahama boiler are due to water flow switches,originally designed to be used in air flow,but in their infinate wisdom Baxi decided to use them in this boiler.Alternativeley you can obtain a fixed price...
  5. M

    Baxi 80 Eco problem

    Option one,call Heat-team for a guaranteed repair including parts for £180.Option two,call British Gas,same as above,for £130.It would be of interest to others who view this public forum,to post a reply regarding the outcome.
  6. M

    Myson Apollo 30/50 Pilot won't stay lit

    Looks likeley that the gas valve is due for renewal.
  7. M

    potterton combi 80 cuts in and out.

    As Tony says,renew complete diverter valve assembly.
  8. M

    HOW TO REMOVE A PUMA DIVERTER VALVE ??

    Rothenberger pump pliars will grab the backnut,if after previous post comment to bend back ninety degree metal sheet.Also a liberal spray of w.d.40 on aforementioned backnut should make it easier.I used to work on a local authority contract with in excess of 1200 of these boilers installed.Real...
  9. M

    combi valiant boiler

    Pressure drop may be due to a water leak somewhere on your heating system,or thro the pressure relief valve.Check the pipe passing to outside is not dripping.
  10. M

    2 pump system

    Do a search on honeywell.On this site you will find all the answers you need.sugest honeywell y plan.
  11. M

    3 way valve y-plan problems

    Sounds like the valve motor is knackered.An easy diy job to renew the synchron motor within valve head.Available from Partscenter.
  12. M

    Potterton Lynx 2 - replace pcb

    Personally ,I would not trust anything that you buy from e-bay,as it is not covered by the sale of goods act.Try a search on google for gas boiler spare parts,quite a few good suppliers.Alternativeley ,you can make a request on this forum.
  13. M

    NO DHW on Vailant 242e or 282e **UPDATE**

    Boiler details normally on underside of combustion box.
  14. M

    Baxi Bahama 100 Combi Boiler

    Two things possibly the problem.There should be a steel mesh filter installed above boiler isolating valves.Can:t remember if flow or return,check manual.This must be clear.Also the three port valve is fitted with an internal honeywell plastic cartridge.These are well known to become jammed or...
  15. M

    Potterton Profile Boiler

    recomend that you install a new grundfos 15-50 pump.
  16. M

    What boiler? Rough price guestimates?

    The potterton range of powermax boilers are condensing with an inbuilt store between 85 to 155 litres ,giving up to 40 litres per minute,{until store is depleted].Worth a search.A very expensive piece of kit,but everything in one unit.No need for cylinder or megaflo.All valves,pump,pressure...
  17. M

    HW must be on with CH

    Yes,save loads on your gas bill.
  18. M

    Worcester 240 playing up

    Hello mr. flair.Regarding your problem with your boiler,how old is the appliance?.Has it been regularly serviced?Cyberspace answer to your problem,have boiler serviced by an engineer with experiance of this boiler,and, possibly a full chemical pwerflush.Hope this is of some help,Mike.
  19. M

    HW but no CH - Central Heating Problem

    Good evening Kushdy,from your recent posts,it seems that you have a fully pumped heating system.You have stated that your domestic hot water side of things is operating correctly.This implies that your boiler and pump are operating correctly.The system will therefore be operated by a three port...
  20. M

    No HW or CH

    Good evening Ian,the problem may be that you have a pressurised boiler system.Removing and then re-fitting radiators,could result in no system pressure.Check to see if you have an internal water pressure gauge at your boiler.Normally a circular gauge on lower front right of boiler ,with an...