Search results

  1. M

    Newly installed combi

    Caius,sorry to hear that you have had bad service from a corgi guy.As previous posts have advised,installation of thermostatic radiator valves, and a boiler interlock(room thermostat},should solve your problems.This will prevent boiler cycling.Good luck,Mike.
  2. M

    building

    Thank you Mr. Winston for your very prompt reply to my recent enquiry.As you have seen in my post ,I am concerned with regard to cutting through existing block and beam roof, into proposed loft area.I do not wish to waste money on a job which is not feasible.Thanks again for your interest in my...
  3. M

    building

    Hello everyone,good site.I own a flat roofed property built in 1942,with solid concrete floors.The roof is constructed of block and beam,with an asphalt finish,overlaid with insulation and some type of roofing felt.This is obviously causing problems with damp and water ingress.I intend to have a...
  4. M

    buying combi system

    You have a choice of either opting for a combination boiler or a system which really meets your requirements.All new boilers ,by law,must be condensing.Combi boilers areo.k.,as long as you ensure that the flowrate for hot water is adequate for your needs.The normal rule applies,the more money...
  5. M

    Fitting shower tray

    In a way you have already answered the question yourself.Are you installing this shower tray on a concrete sold floor, or a suspended wooden floor?
  6. M

    combi boilers

    As of the 01/04/05 ,all new boiler installations, must comply with current regulations.This means that all boilers,unless they fulfill an excemption, are to be high efficiency condensing boilers.Also upon installation ,the localcouncil building control officer must be informed of the...
  7. M

    Potterton Boiler doesn't work

    Suprima boiler problem is almost certainly down to a defective printed circuit board.Potterton have a new board, complete with wiring harness.Check previous threads on this boiler,it will take you a few hours.
  8. M

    worcester 240 rsf

    No, it does not seem likeley that it is the diverter valve.The problem is more than likeley to be the pressure vessel is u/s. Boiler overpressuring and then dumping water outside thro pressure relief valve.
  9. M

    Potterton puma CH keeps cutting out but hot water still work

    Ensure that there are not any water leaks or dripping taps on the hot water side of boiler.This would prevent correct operation of the wax capsule diverter valve from opening to the heating flow.Also check pump is operating,auto air valve,pressure vessel at correct air pressure.Finally ensure...
  10. M

    vaillant boiler

    More details please,boiler model and type,how old,etc?
  11. M

    BOILER REPLACEMENT

    plumbcenter can offer you an ideal classic boiler, in sedbunk rating :b;condensing boiler ,but badged under their own brand name.Reasonable price,check it out on their website.
  12. M

    DIY SAXOPHONIST.

    Central Heating,strange customer.Normal day,get to my third promised am. call to service a worcester boiler.As normal,I always ask ,;Is the boiler giving satisfactory performance,any problems with heating or hot water?No, says thje customer,everything working fine,just a service.[Boiler has not...
  13. M

    Engineer required for a job in the Liverpool area

    Just re typed my e/mail adress in profile,mail me again,if you still require help,mike.
  14. M

    worcester 24i

    From your post, and limited description of boiler fault,my response is that it is a failure of your diverter valve,more boiler info is required.Have you checked internal boiler pressure as indicated on gauge?Is the pump operating?Is the auto air valve working correctly?
  15. M

    Engineer required for a job in the Liverpool area

    Check my profile for contact details,I llive on the Wirral, but still do a lot of work in :the Pool:.I am a registered corgi engineer.
  16. M

    Poterton Puma 80 - Several problems

    More info required please.Is the boiler the permanent pilot or electronic ignition model?Permanent pilot type model has a two speed fan,electronic ignition type has a single speed fan.How old is the boiler?Are there any water leaks on the domestic hot pipework or dripping taps?If so this will...
  17. M

    Best Combi Boilers

    A major manufacturer is now offering a solid 5 year guarantee on its condensing combi range of boilers,with the proviso that the boiler is serviced yearly by a legit corgi registered company.
  18. M

    Baxi (rm512?) hw works, no ch

    Sounds as though the problem is with motor fitted within the zone valve.This motor,when it receives a switched live supply ,from room or cylinder stat ,moves into heating/hot water mode,and then auxillary switch operates,sending live supply to boiler and pump.A new sychron motor is about 18 quid...
  19. M

    WORCESTER 24CDI DIVERTER VALVE

    Hello everyone,new to this forum.I would appreciate an answer to this question.How much would it cost to replace the diverter valve on a 24cdi combi boiler?Grateful for any replies.
Back