  1. D

    sealing shower tray onto floorboards + tanking

    that is contary to what most people say on this site people recommend tanking shower areahence why i bought the kit!! does the plastic sheeeting supplied in kit go onto floor over floorboards and then obviously tank walls and use sealing strip on joins?????????? thanks
  2. D

    sealing shower tray onto floorboards + tanking

    im about to fit a low profile stone resin quadrant tray direct onto floorboards.. flooorboard are solid no movement,,,, ive also brought some easybath tanking also couple questions whats best to bed shower tray down with ??? i fear sand cement mix would crack up over time how do i seal...
  3. D

    low profile shower tray onto floorboards & tanking

    im about to fit a low profile stone resin quadrant tray direct onto floorboards.. flooorboard are solid no movement,,,, ive also brought some easybath tanking also couple questions whats best to bed shower tray down with ??? i fear sand cement mix would crack up over time how do i seal...
  4. D

    double oven and hob off same supply

    Can i just say ..just found out .,answers above are wrong because at the end of the day there is a 40a rcbo at cu and 4mm feeding appliances from ccu .......... the breaker cannot be used in this situation ... 4mm cable on 40a cb 4mm cable clipped direct can only handle 37a
  5. D

    split load board zs on cert

    what do you put for maximum zs value on a split load board ring circuit protected by 30ma rcd do you look at tables in regs book or is it just 1667 thanks
  6. D

    measured zs too high vs calculated

    i would say they are perfect results apart from zs
  7. D

    measured zs too high vs calculated

    Just foundthis seems to resemble my situation but would zs calculated vs measured be 0.30 apart?? >>>>>>>>>>>> it is a possibility that your measured values of Zs were obtained using an earth fault loop impedance test instrument employing some form of ‘soft test’ facility that does not...
  8. D

    measured zs too high vs calculated

    ze is fine its just the zs calculated and zs measured that looked odd it is 32a type protected by rcd circuit
  9. D

    measured zs too high vs calculated

    zs measures 0.60
  10. D

    measured zs too high vs calculated

    it is ring circuit Ze 0.08 readings taken from socket outlet(easier) L-L 0.35 N-N 0.35 E - E 0.60 CROSS L-N 0.15 CROSS L-E 0.24 From this now the calculated value of zs = 0.32 is this correct yes ze +(r1+r2) just looked at my regs book again and it is within permissable max zs...
  11. D

    measured zs too high vs calculated

    sce4nario measured zs with meter too high! above max permissible zs but calculated value is well within specification what gives?? is the circuit ok? what do i do on test results?? thanks
  12. D

    CAPPING hate putting on this stuff (is it just me?)

    make it sound dead easy but not in reality when your trying to drive your nail into engineering brick or rock hard mortar
  13. D

    CAPPING hate putting on this stuff (is it just me?)

    i thought it was requirement not good practice
  14. D

    CAPPING hate putting on this stuff (is it just me?)

    Hate putting metal capping on to cover cables . I know we have to do it ..but banging fingers! nails jumping out .. capping pops off grrrrrrrrrrrr any easier ways????
  15. D

    New shower tray & enclosure making watertight

    whats tanking it??????????
  16. D

    New shower tray & enclosure making watertight

    About to install low profile shower tray whats the best way to ensurethat this will be forever leak free? do i recess it into the wall slightly ? use some kind of sealant strip or plastic sheeting against wall or just sealant?? thanks
  17. D

    double oven and hob off same supply

    remember the 4mm is only feeding appliances from ccu like i say no way would 6mm fit into hob nor oven terminals!! obviously why 4mm was used in first place as far as i can see...
  18. D

    double oven and hob off same supply

    so all works out great :D :D :D :D :D because i had a look at hob and oven connections and there is absolutely no way in this world i can see 6mm cables gettin in the terminals
  19. D

    double oven and hob off same supply

    this is what i have electric cooker and hob 40a rcbo at consumer unit 6mm twin and earth feeding ccu (type with 13a socket on it) cable is about 5 metres long clipped direct to joists double oven says it rated at 20 amps hob 6kw oven and hob are both fed with individual 4mm cables...
  20. D

    double oven and hob opposite sides of room

    nope both electric thats why i want to daisy chain the feed cable to supply both appliances hob & oven