Search results

  1. D

    strange end to end continuity ring main readings

    safe to say that all readings ok then just parallel earths??
  2. D

    help with new consumer unit and tripping RCD

    youve also got exposed live contacts from the busbar..
  3. D

    help with new consumer unit and tripping RCD

    your neutrals for the ring main look to be on the non - rcd side wired incorrectly
  4. D

    strange end to end continuity ring main readings

    can anyone help to interpret these ring main readings end to end tests L-L 0.46 N-N 0.45 E- E 0.30 The ring is wired in 2.5 mm twin + earth 1.5mm cpc so reading on cpc continuity should be higher dont know why this is . further tests x-link L - N 0.23 0.23 0.23 0.23...
  5. D

    metal main incomer

    outskirts of wolverhampton this 1
  6. D

    metal main incomer

    what should i should put on EIC with cutout in its present form??? leave it blank????
  7. D

    metal main incomer

    didnt think it would be quite that easy to post pic :D what do you put on eic ...for this type of cutout no info, rating anything anywhere and not meant to break seal thanks
  8. D

    metal main incomer

    http://i223.photobucket.com/albums/dd46/darrenbergin/DSC00020.jpg http://i223.photobucket.com/albums/dd46/darrenbergin/DSC00018.jpg
  9. D

    metal main incomer

    mains incoming cable goes into big old looking metal case PMS, with no visible fuse. Nothing like the normal plastic jobs we see every day. Does anybody know if this is still ok ? when doing an install, say consumer unit..what information would be put on the type and rating of supply...
  10. D

    maximum disconnection times

    also if its a split load board would this make a difference thanks
  11. D

    maximum disconnection times

    for typical domestic circuits what would you put on eic forms for each circuit under column " maximum disconnection time permitted (s) " thanks
  12. D

    split load board rcd ze

    on rcd protected side of split load board do u have to note zs values on eic because ordinarily if zs couldnt be met then circuit could be protected by rcd..
  13. D

    consumer unit change- filling in eic deviations

    yes main bonding is all up to scratch and supplementary bonding is below 0.05 ohms but there is no supplementary bonding directly to rads and taps in bathroom. I suspect reading is ok because boiler is directly below bathroom so within metre/couple of metres and is all cross bonded.. is...
  14. D

    consumer unit change- filling in eic deviations

    so shower doesnt need doing but to bring up to current standards must the supplementary bonding be done in bathroom? and sleeve cpc's everywhere or make a note on eic that its missing also supplementary bonding has not been done in bathroom but if tested using a low resistance ohmeter...
  15. D

    consumer unit change- filling in eic deviations

    When changing consumer unit to new split load type noted during installation and testing that there is no supplementary bonding in bathroom, shower has no pull cord isolating switch , no sleeving on cpc's would these all be noted on eic or would the work have to be carried out to bring up to...
  16. D

    insulation resistance test split load board

    so is it ok to link phase + neutral incoming and do insulation resistance to earth on whole installation. will this save damage to rcd on typical split load board? thanks
  17. D

    insulation resistance test split load board

    hi all is it ok to do an insulation resistance test on the whole of a split load board and associated circuits at incoming meter tails or will the test cause damage to the split load rcd a lot of rcd says they must be disconnected when doing insulation resistance test or damage will occur...
  18. D

    megger 1502/2 live tests psc scale

    has anybody got this meter the psc scale is not very clear can somebody explain the function of the four positions on dial thanks
  19. D

    ring circuit continuity test x- link results

    i am a new to testing and testing my own house at moment using a megger 1502/2 ring continuity is ok but cross linking phase + neutral and phase + earth gives spurious results I am using a "socket and see" plug-in connected to megger thanks
  20. D

    ring circuit continuity test x- link results

    hi can anyone explain these results and possible fix on continuity tests of a ring circuit x-link phase+neutral skt 1 0.19 skt 2 0.15 skt 3 0.24 skt 4 0.21 skt 5 0.14 x- link phase + earth skt 1 0.49 skt 2 0.31 skt 3 0.50 skt 4 0.61 skt 5 0.27 thanks