Search results

  1. T

    hot water

    if there is no service valve on the cold feed into the boiler turn off the cold at the mains , open the hot tap , change the valve , turn on water again .
  2. T

    super room stat

    They are volt free or volt switching it doesnt matter which sytem it is used on , it make the circuit whether it is switching no voltage or up to 240 v
  3. T

    super room stat

    Connect l and l1 they make the circuit , doesnt matter if they are switching voltage or not , it is capable of volt free or up to 240v switching
  4. T

    relocate the bathroom

    If you can route a soil pipe from the drains to where you want to put the new bathroom with enough fall on it then its ok ,or you could use a macerator which I personally hate and would only use as a last resort .
  5. T

    Air switch on toilet

    it is just a round chrome one mounted on the woden panel with a tube connected , there are no markings on it, any make would do as long as the tube size is the same.
  6. T

    Air switch on toilet

    Ive been to a house which has a concealed cistern with an air switch operated syphon , the syphon works fine but the air pressure has broken , I have been to plumb center who said they cant get one , If I have to I will have to get a syphon with a cable on it and replace the whole thing i will...
  7. T

    daewoo lanos cutting out

    Father in law has one and it runs fine with no missfire but has started cutting out when you come to a stop , it starts again fine . I had this problem ona vectra and it was an idle air valve that gets bunged up . does this car have one it sounds very similar to the problem I had with my old...
  8. T

    Worcester 28Si 11 combi boiler

    worcester bosch website
  9. T

    Ideal Sprint Combi Boiler No Hot Water

    from that discription it could be anything , more info would be nice
  10. T

    BT Master socket/ wiring

    you should have 50v dc on a normal phone line ie a live and an earth this is what you need to connect to , is your house fed via an underground cable or an overhead cable???
  11. T

    Baxi bermuda 401 boiler - hot water ok - no heating - help!

    sounds like motorised valve is knackered
  12. T

    PLEASE Help Me !!!!!!

    Is it the large plastic tank or the little plastic tank???
  13. T

    Leaking WM standpipe trap.

    undo the nut wrap some ptfe tape around the threads and the seal and tighten the nut back up
  14. T

    Worcester boilers

    Aboiler can only deliver good flow and pressure if you incoming mains has it , no mater what boiler you fit it can only supply what is coming in , ie if you are on a shared main it will be bad or your local area might not have very good water pressure even if you are on your own supply.
  15. T

    Confusion over pressure readings of combi boiler

    the white plastic pipe is the condensate pipe and yes it is perfectly normal for it to have water running through it so that is normal , as for pressure dont worry about it sometimes it will rise sometimes it wont it depends on your size of system etc as long as the pressure is about 1.0 when...
  16. T

    Rerouting internal telephone cable

    normal pstn phone lines dont get "parked " in the ex , an isdn might but normal pstn or dsl lines dont
  17. T

    Rerouting internal telephone cable

    leaving the wires open circuit will not look like a phone off the hook it will let anyone trying to call you hear a ringing tone but obviously your phone wont ring as it isnt connected , to give an engaged tone to a caller loop the wires together shorting the line out this gives the impression...
  18. T

    Pop up waste doesnt lift up enough for water to drain

    if it lifts out of the plughole there will be a screw on the bottom of it undo the locknut and screw it out a bit further then tighten up the locknut .
  19. T

    Rerouting internal telephone cable

    You dont need to isolate them the voltage is 50v but will only give you a tingle , nothing dangerous and even if you let them touch it will not do any damage to phones , sockets or the phone line itself .
Back