  1. K

    high ze reading

    thanks all, i will contact dno in the morning, dose any of you guys have the number?
  2. K

    high ze reading

    using a 3 lead test kit if i put one probe on the line and the other 2 probes on the neutral i get 0.14 ohms
  3. K

    high ze reading

    at the consummer unit, all parallel paths removed ect, and tried two different test kits
  4. K

    high ze reading

    any advice on this, tn-s system giving me a reading of 2.80 ohms :roll:
  5. K

    socket and switches hights for disabled

    im thinking of putting the sockets 600mm to the bottom and the switches 100mm to the top wont look nice :lol:
  6. K

    socket and switches hights for disabled

    just want to know the socket and switch hights for disabled in a wheel chair thanks
  7. K

    periodics

    rf i understand were you are coming from but i think my question was reasonable the other lads comments straight forward. (not making people look small)
  8. K

    periodics

    rf lighting listen the only way 2 get exsperiance is sometimes by asking why is there always someone has to pop state somthing that trys to belittle people the reason being is if someone was to nock a nail in the wall ect and hit the di cable thats why :twisted:
  9. K

    periodics

    thanks lectrician so would you still code it and make a note? and what code
  10. K

    periodics

    hello all im just doing a periodic on a 3 bedroom house all good but one concern is some of the 2way lighting feeds have single double insullated lives with no earth, the fittings and switch gear the single cables are going to do have an earth off the other twin and earth cables my...
  11. K

    certification

    the main cutout fuse is not getting installed untill after christmas it had to be disconnected from outside (it was in a bad way) im sure the council will be asking me to go back anyway but just thought i would get a bit of edvice off you,s who have proberly got 10 years more than me thanks...
  12. K

    certification

    the ei cert i issued i wrote the front of it dead test only so when it dose get energised do i just issue them with another ei cert after i have done all tests?
  13. K

    certification

    i no what you are sayig but i had to hand a cert to the council so eon ect can come and fit the meter would i need to issue another cert or not?
  14. K

    certification

    alright all i have just finished a complete rewire on a house after a fire there is no main fuse meter ect, (waiting for them to be fitted after fire) i have done a dead test and isued the local council who im doing the job for a electrical installation cert all i need to no is do...
  15. K

    earth goes where?

    dont put the earth in any of the terminals live , slave ,load. ensure that the metal back box for the switch is earthed what do you mean by metal plate?
  16. K

    minor works certs

    alright all done a job for a client i reposistiond two lights but i am unable 2 put the lighting circuit on the rcd side of the ccu because of borrowd neutral ect can i still isue a minor works cert even though i cant put a rcd on the circuit? the client dosent want me to sort it out can i...
  17. K

    Do I need to report this one?

    report it :wink: there is trunking going to the cooker socket and trunkig going out so i bet there is a cooker outlet down the back of the cooker and the clown who fitted it dident no what a cooker outlet is :lol:
  18. K

    test results

    true :lol:
  19. K

    test results

    i work for a maintenance firm as there inhouse electrician and we also have subbies anyway i was looking at one of there pir,s and i noticed the readings on the ringmain sockets was a bit out on the continuity readings were L=o.44ohms n= 0.67ohms and the cpc was= 0.77 doing the quick...
  20. K

    Depth to chase out electrical cables to

    good point