Search results

  1. P

    Power shower

    taydo, you said it was illegal to use a pump on a mains water supply but in the water regs guide G6.1 says that you only need written approval from the water undertaker if a pump connected directly or indirectly to the supply pipe draws more than 0.2 litres per second.
  2. P

    Lots of probs with CH and HW - please help

    why don't you get them back in? You've paid a lot of money so they should leave you with a properly functioning system. If they can't make it function properly shouldn't they pay the cost of someone else coming in to fix the problems for you?
  3. P

    stiff hot water valve

    taydo have you experienced a gatevalve falling apart just turning it by hand?
  4. P

    stiff hot water valve

    I want to change a washer on someone's hot water tap but the stopcock between the cistern and the hot water cylinder is too stiff to turn off by hand. If I put a screwdriver in the stopcock wheel to get more leverage I'm scared that I'll deform the copper pipes. Any tips on what I can do apart...
  5. P

    Baxi Barcelona Lockout

    is this a record for the number of replies to a query?
  6. P

    Therostatic Mixer Shower has low pressure

    There are two ways to boost pressure: booster pump or raising the height of the cistern. Which is low pressure, the hot or the cold or both?
  7. P

    plumber's fear

    Thanks for the support guys
  8. P

    15mm plastic pipe to 15mm copper using compression

    yes you put an insert in the plastic pipe if you want to use a compression fitting
  9. P

    plumber's fear

    I know this isn't a counselling forum but are there any other college based trainee plumbers out there who have little experience or real plumbing situations in people houses who feel anxious and start imagining flooding people's houses every time they are asked to do the simplest of jobs? A...
  10. P

    lead pipe

    How did the plumber cap it off inside the house?
  11. P

    Fitting a new Toliet Pan & Cistern

    Have you thought about contacting the cistern manufacturer and asking them?
  12. P

    HOT TAP - WHICH SIDE OF BASIN?

    On my plumbing course a few weeks ago the tutor asked us this very question. She said that the reason that hot taps are traditionally on the left is for blind people. She didn't say that there was a regulation about it. If I was blind, however, I don't think I would trust plumbers to always put...
  13. P

    Solvent weld/push fit waste: daft question?

    sterose if you can't use ordinary white pipes on pushfit fittings then what type of white pipes are you supposed to use?
  14. P

    Water Pressure

    What will you do if the water pressure isn't high enough?
  15. P

    hw in f+e tank

    John Reginald's book "Central Heating" states that pumping over (water coming out of the vent pipe) is usually caused by the cold feed and expansion pipe being connected to the return and with the circulating pump being between this connection and the boiler. Unless the vent pipe is high enough...
  16. P

    hw in f+e tank

    My understanding is that the optimal position for the pump is after the vent and feed pipes on the flow pipe. Also the vent and feed pipes should not be further than 150mm apart on the main pipe. This is copied from "Plumbing" by Treloar: "The cistern must be placed in such a location that...
  17. P

    hw in f+e tank

    where exactly is the pump on the pipework? It should be after the connection to the vent, not before.
  18. P

    High pressure ball valve...

    that I don't know!
  19. P

    cold water tank..

    How about turning the water off via the stopcock outside your house if your neighbour doesnt mind.
  20. P

    High pressure ball valve...

    part 2 is called a diaphragm valve. The white thing that looks like a switch is where the water comes out. Part one is an equilibrium valve