  1. R

    Sink waste outlet pipe

    Hi reading a lot of posts about this and how the outlet pipe needs to be around 16” or so inches from the ground outside. My question is that I have to cut the outlet hole but want to avoid that unsightly pipe on the outside and want to have most of vertical pipe within the sink unit and when...
  2. R

    Tiling on underfloor heating liquid screed

    Thanks- didn’t wana use too much adhesive to stick Mat to floor I will see what’s available my trowel is 12mm for sticking on tiles.
  3. R

    Tiling on underfloor heating liquid screed

    hi, what size trowel notch did you use for sticking the matt down to the floor?
  4. R

    Tiling on underfloor heating liquid screed

    Thanks mr chibs. I will get the same primer from local store. I will try the proflex to stick the mat to the floor and see how it goes.
  5. R

    Tiling on underfloor heating liquid screed

    Hi I am looking to start tiling on a new project. Have installed underfloor heating pipe work and had liquid screed poured on about 3 months ago. Heating working fine. I have had the floor polished as well. I have brought proflex so s1 bags to lay the tiles and have brought durables rolls. So...
  6. R

    Texecom UDL password wrong issue

    ok made some progress here. looks like the panel lost the fact that comip was setup on com1, added that along with the ip addresses for comip as per the comip manual. made the test call successfully. so connection via app and wintex works. issue now is i cant set the alarm cos of No ATS...
  7. R

    Texecom UDL password wrong issue

    Hi The internal ip address is correct and as expected within the control panel . I can ping successfully the ip from computer and when I enter in the ip address into web browser I get the comip layout diagram. Don’t think I’m using away from home but got port forwarding already setup as part...
  8. R

    Texecom UDL password wrong issue

    version 8.2 im using, trying to connect over network as i have the comip hard wired option also trying to connect via the iphone app
  9. R

    Texecom UDL password wrong issue

    still got the same issue with version 8 of wintex. "Connection with control panel could not be established - Please check settings and try again!"
  10. R

    Texecom UDL password wrong issue

    Can’t get in via winter. Used to be able to but when using the same wintex creds it says can’t connect
  11. R

    Texecom UDL password wrong issue

    I’ve tried to do a factory reset by opening the lid, turning off mains and disconnecting battery, turning on power and pressing tamper switch 3 times. Still have the same codes present. So guess it didn’t work.
  12. R

    Texecom UDL password wrong issue

    Found the option in panel and the udl code is what I’m expecting and set to in and wintex
  13. R

    Texecom UDL password wrong issue

    Hi I can’t seem to get into engineer mode now I have 2 codes, one was arming user and one other one an engineer user. When I type in engineer code it was welcome master but when I press 7 I get nothing - when I press menu, there is an option to enable engineer mode which doesn’t really give me...
  14. R

    Texecom UDL password wrong issue

    Hi everyone, got this issue with alarm system Texecom premier elite with the hard wired comic module where I had builders in and they messed up sensor wiring. The panel eventually got locked out and I had to use wintex to enter a code to get another code out to unlock the panel. All worked...
  15. R

    Hive and Worcester Bosch 35cdi Issue

    So have connected this up and boiler has 1.5 bar pressure and initially starts up, but when I try and use hot water, it comes up with C6 error code. I can see power going up to the fan, so not sure how bad the damage is…checked 3 fuses on circuit board and they all ok. I’m hoping fan doesn’t...
  16. R

    Hive and Worcester Bosch 35cdi Issue

    Thanks - I wasn’t 100% sure but thought it was from other threads
  17. R

    Hive and Worcester Bosch 35cdi Issue

    Hi guys - I’ve had some work done and the receiver part of the hive setup has been ripped off the wall. Meaning I have lost all the connections. I have taken pics of the boiler side and have connected up the receiver side part from 1 cable which I’m not sure where it goes? Switch is off atm so...
  18. R

    Ryobi RLT26CDS - Not starting - Air bubbles in return

    Thanks burnerman, I know where I’d rather be… So I’ll try that but always the case when I switch to run mode, the engine splutters and cuts out, only runs when the choke is on/carb flap closed. It did start consistently when I had my hand on the throttle and choke forced on, but last time I...
  19. R

    Ryobi RLT26CDS - Not starting - Air bubbles in return

    Hi John, a trickle of fuel came out when I took out the plug and pulled about 10times. Plug was kind of wet black. Put back in and still the same after I cleaned up spark plug. Even starting with the accelerator pressed and carb flap closed it still didn’t start up. Binning it isn’t an option...
  20. R

    Ryobi RLT26CDS - Not starting - Air bubbles in return

    Hi couldn’t find my spanner to remove the spark but got the strimmer to start consistently by pressing the accelerator with the choke switch down - opposite direction of when I press the lever - starts ok but every time the carb flap opens, it starts to cut out. I’ve tweaked the screws but still...