  1. Untitled

    Untitled

  2. Untitled

    Untitled

  3. Boiler

    Boiler

    Vokera 20 80 rs flowmatic
  4. G

    Combi problem

    Hi lads, Well, I've bled the secondary heat exchanger with c/h on, and it seemed quite a bit of air came out. However, I haven't followed wergas's additional instructions. Weargas, when you say "adjust pressure with it all shut down", do you mean back at the expansion vessel after I've...
  5. G

    Combi problem

    Thanks for taking the time to reply Mick. That No.8 on the manual diagram? Can I bleed that with the system on/hot, or should I switch it off? Thanks again for your help. Gary
  6. G

    Combi problem

    With the combi, not the missus!!
  7. G

    Combi problem

    Hi there, I have a problem with my Vokera 20 - 80 RS Flowmatic. It was losing pressure over a period of time. After checking all the rads, I traced the leak to a faulty c/h flow/return valve. I replaced it, and a suspect leaky PRV. I have also repressurised the expansion vessel to 0.7bar...
  8. G

    Dual Flush Cistern keeps filling

    there are a few methods for fixing the pushbutton. I've seen a version where you pull out the two buttons revealing a screw which you undo to allow the removal of the outer ring from the lid. In the other more common version the outer ring unscrews, however I have had them glued in!! Good luck.
  9. G

    Flow/return valves serviceable?

    Thanks Softus. Yes, it has a large double lugged red lever that looks as if it's held on with a hex bolt. I suppose it's a new one then. You know, I've only been plumbing for about 3 years, but I can count on one hand the number of stopcocks/isolation valves that actually do what...
  10. G

    Flow/return valves serviceable?

    Hi have a Vokera 20 80 RS fllowmatic that is leaking underneath from the large central heating flow/return valve. Leak seems to be coming from the open/close lever. My question is, are these valves serviceable. If so, is it a washer, or tightening a gland...? Thanks for your help. Gary
  11. G

    Halogen downlighter cable

    Any ideas? btw they are running off a transformer.
  12. G

    Halogen downlighter cable

    Hi there, I was installing a triple pack of halogen downlighters. I drilled the holes in the ceiling, fitted the light fittings into holes and climbed into the loft to feed the wire thru the fitting to take the bulb. My problem occurs at this point. The length of wire supplied in the pack isn't...
  13. G

    40mm waste into 4" Soil pipe

    Thanks for the fast replies lads. Sorry Seco Service, do you mean the 40mm abs wont last underground? Thanks again for your help. Gary
  14. G

    40mm waste into 4" Soil pipe

    Hi, Can you tell me if there is anything wrong with solvent bossing a 40mm abs waste into a 4" soil pipe, then covering with soil outdoors? Would building control have any issues wih it? Many thanks, Gary.
  15. G

    Solvent weld waste in concrete

    Thanks for your help mate. Job's done, so I was hoping someone would confirm it's ok! Put in a run of 1:19, will that be enough?
  16. G

    Solvent weld waste in concrete

    Hi there, Can anyone tell me if it's ok to sink a 40mm solvent weld waste pipe into a concrete screed? Ta.
  17. G

    BAXI WM 381 RS Boiler

    I have a BAXI WM 381 RS boiler, and was wondering if this boiler would allow me to run a thermostatic shower off of it? Thanks in advance.
  18. G

    32mm sink waste

    Thanks softus. Where the 40mm comes up thru the floor, it has been cut off flush with the level of the floor. Then they have slid the 32mm from the sink into the 40mm without any seal/connection. Tried sealing it off with some plumbers mate, but water still finding its way out. So I need a...
  19. G

    32mm sink waste

    Sorry, abs is another term for solvent weld. thanks for taking the time to reply. Gary.
  20. G

    32mm sink waste

    Hi there, does anyone know if I can get a male 40mm to 32mm female end abs connector for a bathroom sink waste pipe. 32mm Waste from sink currently sits inside a 40mm waste that is flush with a tiled floor, but is leaking, so I'm unable to get enough on it for a multifit connector or an abs...