Search results

  1. SMG

    Soil Air Admittance Valve Position

    Because the soil vent is lower than the pan, & there is no room for the extra height. I can fit a boss with a 40mm waste pipe, terminating high enough for the water not to flow over, I`m wondering if a 40mm air admittance valve will allow enough air into the soil so the toilet wont gurgle.
  2. SMG

    Soil Air Admittance Valve Position

    My downstairs loo has an air admittance valve which does not reach the height of the water cistern. Its impossible to raise the height where its located. Could I remove & blank the existing vent, then use a 40mm strap on boss with a smaller air admittance valve? Like This...
  3. SMG

    Dry lining box

    Cracking, just the job, thanks.
  4. SMG

    Dry lining box

    I have a static caravan & I have a double socket fitted on a wall. The dry lining box is broken, irreparable. Does anyone know where I can acquire a dry lining box, 25mm deep. 35mm boxes are too deep for the narrow cavity. Some light switch dry lining boxes are standard 35mm deep, but have a...
  5. SMG

    12v DC LED Bulb Polarity

    At least we know now, Thanks.
  6. SMG

    12v DC LED Bulb Polarity

    Just a footnote to this, I bought a DC LED Driver, & DC bulbs. connect the bulbs either way round & they work fine. In the words of old Harry Worth, "I don't know why but there it is".
  7. SMG

    12v DC LED Bulb Polarity

    I "sort of" understand where you guys are coming from regarding rectifiers, apparently there is a small circuit board inside the 12v led bulb, I would assume the electronics would take care of any volt drop & polarity. I didn't want to connect all the bulbs then switch on just to see 8 flashbulbs.
  8. SMG

    12v DC LED Bulb Polarity

    Yes m8, there are "External" drivers & internal only drivers, the latter has a case which allows full cooling,the case is ful of holes, that's the type I am getting. Aparently, the DC bulbs are "Dimmable" but you can only use DC, (I wont be dimming them), the bulb I suspect must have some sort...
  9. SMG

    12v DC LED Bulb Polarity

    Thanks for those reply's, I plan to fit the driver unit in the loft, where there is plenty of ventilation. Each bulb has its own connection, & all 8 connect to a terminal block, which will then connected to the 12v DC driver. The maximum wattage is less than the drivers maximum output. It just...
  10. SMG

    12v DC LED Bulb Polarity

    I am replacing my MR16 halogens with LED`s. I have a new led driver rated at 102watts, & 8 bulbs rated at 94 watts total. In my experience an AC bulb will fit any way around, but a DC bulb is DC, so, which pin is Pos, & which pin is Neg. Or, does the bulb fit either way?? Thanks
  11. SMG

    Pipe banging

    Just a quick update. I replaced the TMV with another, same banging, fitted another TMV in the upstairs bathroom, lo & behold, more pipes bang. For some reason the TMV is creating the fault, the hydraulic shock, Without the mixing valves there is no pipe hammer at all? Very strange.
  12. SMG

    Pipe banging

    The feed pipes are behind the plasterboard wall, behind the units, its impossible to access them. The only way I could "Stabilise" them would be to drill a few holes, very carefully, & inject expanding foam in, I was kinda hoping the valve was duff. One thing I don't understand is why the...
  13. SMG

    Wheels coming out of ceiling in bathroom?

    We used to call it a "Rack", most were held by clothes line, lower it down, load it with damp washing, & hoist it back up.
  14. SMG

    Pipe banging

    I fitted a Prestex P404 TRV under my wet-room sink. Water pressure is a steady 3 bar, balanced hot / cold feed. Before, there was no noise, no hammer, now, whenever I turn the tap off, I get pipe bang. Just one bang each time, & it only does it when the tap is on hot (Mono tap with 10mm tails)...
  15. SMG

    Jacuzzi spa bath pipe cleaner

    Nice friendly reply from Cascade, they don't sell it here & they don't know of an equivalent. Thanks Cascade.
  16. SMG

    Prestex P 404 TMV 2

    Yes m8, it just dawned on me that the system runs between 60 / 65 degrees, problem solved, kitchen sink doesn't really need one. Thanks.
  17. SMG

    Prestex P 404 TMV 2

    Thanks, its a private house, (Mine) to feed the sink & 1 wash hand basin. Both fed by 15mm copper, both sinks using flexible tails at the tap. Hot & cold on mains, 3 bar.
  18. SMG

    Prestex P 404 TMV 2

    Can I use 1 thermostatic mixing valve to feed 3 sinks? Or do I have to fit 1 per sink? TiA
  19. SMG

    Jacuzzi spa bath pipe cleaner

    Thanks buddy, I just edited my previous with the same idea. If it is, I will post it here.
  20. SMG

    Jacuzzi spa bath pipe cleaner

    Well it does look like I will have to get an alternative, can only try it m8. As long as it shifts the built up crud in the pipes & doesnt discolour the jets, thanks. I might just contact Cascade, the same product may be available under another name.