Search results

  1. BDL

    Ideal 120 Combi no hot water

    No not a sticking solenoid a sticking valve. Just curious because I have changed 2 gv's this week that have stuck both in Essex (Grays to be exact).
  2. BDL

    Ideal 120 Combi no hot water

    Your gas valve is stuffed. Warm weather= sticking gas valve. A new valve was introduced by S.I.T. teflon coated to cope with glycol. You should 240vac to gas valve solenoids, but no gas. Where in the Uk are you?
  3. BDL

    Ideal M30100 No HW no CH

    The diverter actuator is playing up. You must have spent some serious pounds to get where you are now? Take the actuator head off, remove molex plug and observe if this cures the fault. A new diverter is available with teflon coated inside to resolve the sticking issues.
  4. BDL

    I'm in the wrong job

    A little sour that. But I guess you agreed to a fixed price job?. If so well that is life. What if the scenario were different? You paid your fixed price and the engineer was there for 4 hrs and changed loads of parts? You would be very happy? Swings and roundabouts in life...
  5. BDL

    Problem with Ideal Icos

    I have had this with 3 I fitted this year. On all of them it was the ignition lead not pushed in tight onto the ignition probe. Black rubber connection to the right of the heat exch.
  6. BDL

    Replacing conventional boiler with combination

    Best diy guide would be to do a 3 year apprenticeship, 5-10 years experience and acs every 5 years. Oh and get corgi.
  7. BDL

    Fitting a Combi DIY Style....?

    Says it all really! You want to remove an Ideal Classic/unvented cylinder and replace with a COMBI?. Why?
  8. BDL

    Ideal Classic FF250 Boiler

    The Ideal Classic is probably the most reliable trouble free boiler I have ever worked on. I am not aware of any inherent design/manufacture problems with this range. The pcb is not problematic, the expansion vessel is common among alot of other manufacturers and reliable. The air pressure...
  9. BDL

    Sign writing

    Thnx Beezer, I tried hot water but no luck. The hair dryer I will try today.
  10. BDL

    Sign writing

    Anyone got any tips on how to remove vinyl signwriting without damaging van? Thnx in advance.
  11. BDL

    CONFUSED

    Plumb Center wrong. Did training on Classic HE and Mexico HE last week. Def. not for gravity. Will post some info in a while.
  12. BDL

    CONFUSED

    The Mexico is HE is a floor standing Icos. It is definetly not compatible with gravity systems.
  13. BDL

    Ideal Response 120 - Any help appreciated

    To be honest with you I would suggest getting someone out to look at the boiler. Make sure the engineer is familiar with the boiler prior to visiting though. If you are within our area take a look at our website and make your own mind up. Could be gas pressure, ignition/detection...
  14. BDL

    Ideal Response 120 - Any help appreciated

    Where abouts in the Uk are you?
  15. BDL

    Ideal Response 120 - Any help appreciated

    Original post states fan runs but will not light. The fan on a Response is an Ebm modulating fan. It works from a fan speed board so does not have bearings. Winnit does the fan run ok prior to attempted ignition?
  16. BDL

    Ideal Response 120 - Any help appreciated

    Suspect a leaking heat exchanger. You really need a corgi out to drop the burner and check for water.
  17. BDL

    Floor standing condensors

    Mexico He can be fitted to sealed system, just add exp vess prv etc to system.
  18. BDL

    Floor standing condensors

    Why not use the twin flue kit? 80mm I believe.
  19. BDL

    Floor standing condensors

    Ideal Mexico He. Floor standing high efficient band A boiler.
  20. BDL

    crap water pressure

    Obvious answer, why didnt you check the pressure BEFORE fitting the shower?
Back