Search results

  1. C

    halstead quattro combi

    call for heat run a tap, fan not spinning pump working d/v switches correctly nothing else
  2. C

    halstead quattro combi

    weargas thanks for the reply with you saying there is no flow switch should i have 240 v at the fan, why do you think it worked for c/h before and not now. thanks
  3. C

    halstead quattro combi

    i have installed a new diverter valve to my wickes 2000 boiler aka halstead quattro due to having no hot water. the boiler will now not fire for c/h or h/w . if i open the hot tap the d/v works as it should the pump runs nothing else after that. the boiler is pressurized to 1.2 bar. before i...
  4. C

    ideal mini 24 combi

    thanks for your post croydoncorgi,i will strip down the gas valve and clean filter as i am corgi registered. they don't teach you everything there is to know on the ccn1 about boilers etc .i only got my corgi 6 months ago i ve got alot to learn yet but thank you for your help :)
  5. C

    ideal mini 24 combi

    hi, i have the above boiler , problem is the there is no hot water.the heating side works perfect the boiler does not make any noise when hot water is called for . the flow rate of water coming out of the hot tap is very poor would this indicate a scaled up dhw heat exchanger. would the poor...
  6. C

    No hot water (Vokera 80 Excel SP)

    where abouts in the goole area are you from
  7. C

    potterton suprima 50 keeps blowing the fuse

    hi , potterton suprima 50 conventional boiler, open vented system. when power is switch on green and red lights come on for approx 3-4 secs, green light then goes out and shortly after that the fuse blows in the fuse spare. the pcb shows signs of scorching if this is faulty would it cause the...
  8. C

    cost for commissioning a combi boiler

    plumber will, it is a gas fired combi
  9. C

    REMOVING A FIREPLACE CHAIR BRICK

    hi there i need to remove a chair brick from a fireplace opening to allow for a inset fire to be installed.does anyone have any experience of doing this any help would be great. thanks
  10. C

    glow worm swiftflow 120 combi

    hi , i have limited info on this problem, the fan on the boiler seems to be hunting for power (1 second bursts) if the tube to the air pressure swith is removed the fan works correctly, when placed back into position the fan hunts for power again. the boiler has had a new air pressure switch...
  11. C

    cost for commissioning a combi boiler

    hi, would any one have an idea what the cost will be for the commissioning a combi boiler in the yorkshire area
  12. C

    central heating calculator

    hi , can anyone tell me if they know of any websites with a c/h calculator on it (size of room, outside walls etc) cheers
  13. C

    vokera combi

    hi galwag, thanks for the post i think it is a diaphram prob but all the help is greatly recieved
  14. C

    vokera combi

    hi dp, cheers for the post, the ch is working its just the hw thats not
  15. C

    vokera combi

    thanks for the quick response ,what is the best way of checking the over heat stat is faulty
  16. C

    vokera combi

    boiler is combi vokera 20/80 rs flowmatic , the ch is working fine but there is no hot water. when hw is drawn from tap its is hot then turns cold within seconds boiler doesn't fire up .if i override the microswitch the boiler fires is this problem probably due toa faulty diverter valve,diaphram...
  17. C

    vokera 20-80 flowmatic combi

    i have limited information on the symptoms ,when hot water is drawn off from the tap it is hot to start with but turns cold after filling about half a bowl . from what i've been told i think the boiler shuts down. the ch is working fine any advice would be appreciated
  18. C

    any recommended books on plumbing/boiler fault finding

    ive only been plumbing for a short while and wanted more info as you know knowledge is power
  19. C

    any recommended books on plumbing/boiler fault finding

    hi cog, basic backgrounds,plumbing and heating systems
  20. C

    Pilot Light Problems

    its sounds like your thermocouple is jiggered