  1. R

    Radiator extension tails

    stelrad 40mm extensions from plumbcentre. O ring seal just like on bleed offs that go into top of rads dont over tighten
  2. R

    one for the gasboard lads

    MI's manufacturers instructions
  3. R

    Copper pipes in screed

    will be ok if wrapped properly but not the best as regards pipe insulation
  4. R

    Propane stove

    Is this new or used? Are you sure that you are following the correct procedure for lighting? Do you have the makers instructions? Some need to be held down to ignite and then turned further whilst still holding them down. What are you going to do in this secluded shed? Tony...
  5. R

    Which parts of shower trap need silicone?

    i would get rid of top washer and use plumbers mait. i would silicone gap c
  6. R

    Calor gas heater

    why not put a co detector in shed you should pick one up for about £15
  7. R

    Vertical radiator heating-up in an odd way

    have you connected the flow & return to correct sides of rad as per mi a lot of these rads wont heat up properly unless flow is on a certain side of rad (usually the left)
  8. R

    What boiler to avoid??

    duo tec is a good boiler
  9. R

    Balancing Rads

    yes
  10. R

    zanussi hob one ring dud

    thanks for that are these easy to change
  11. R

    zanussi hob one ring dud

    one ring has stopped working on electric hob. other 3 ok. what is it likely to be & will i be able to diy.ceramic hob
  12. R

    Central Heating - 2 issues

    do you have a back boiler fuse blowing could be caused by cable into boiler heat damaged seen it happen before
  13. R

    Which combi boiler

    the baxi is a decent boiler vaillant generally regarded as better make but will probably cost more
  14. R

    LPG Cooker fitting question.

    wsts, im not doubting you at all, but just want an explanation, how/why is LPG more dangerous than NG, i have only ever done NG, cheers as namsag says lpg will collect at low level also has lower flammability level than nat gas have seen lpg leaks where we used buckets to collect gas and...
  15. R

    Any alternative to copper for gas?

    So why would you bury on MDPE pipe it needs to be buried as over a period of time sunlight makes it brittle also to protect it from damage eg spade kids traffic etc
  16. R

    LPG cooker and Forklift bottle

    deffo a liquid offtake probably 18kg you certainly cant use it for a hob
  17. R

    Central Heating LPG

    you should run any appliance on one type of fuel only. propane and butane are not the same and it is not safe to run a gas boiler on a fuel it is not designed for.
  18. R

    Gas fire vents

    tamz wrote The input of the fire is irrelevant here i think not. the input of fire has to be added to that of back boiler before taking off the 7kw
  19. R

    back boiler - no water (hot or cold)

    sounds like cold water mains frozen or stuck ball valve in cistern
  20. R

    Vertical rad bottom pipe is toast, rest is cold

    i agree with picasso with a lot of these fancy rads the flow must be on the correct side for it to work (usually flow in on left hand side but not always)