Search results

  1. R

    noisy zanussi

    my zanussi built in oven is very noisy when running and also for quite a while after when switched off. possibly fan noise. only 2 years old and not used excessively
  2. R

    ideal mini hot water not

    ideal mini 24. ch ok . fires up on dhw demand but water only lukewarm at best. changed thermistor and stat to no avail. could it be plate heat exchanger?
  3. R

    Bottled Gas Regs

    I would go for four 47kg bottles with automatic changeover valve. this must have an opso. this way you are increasing offtake capacity by drawing off 2 bottles at one time. also you wil not need deliveries so often
  4. R

    Leaking gas pipes.

    the stuff you need for lpg joints is plasticol x 10. a little of this round the olive will do the job. also when making screwed joints on lpg thread tape alone is not enough. you should smear the thead tape with x10 before screwing joint tight or the lpg will eventually break down ptfe and joint...
  5. R

    Balancing a CH system

    the rad valve is or can be used as the lockshield
  6. R

    vivaro sat nav

    how do i re set it
  7. R

    Which Is Best Sentinel X200 Or Fernox Silencer ?

    i put x200 in a baxi bbu 2 weeks ago worked a treat
  8. R

    vivaro sat nav

    my vivaro infotainment sat nav is playing up. the display is placing the van about 50 mile from where it actually is, and therefore cannot calculate routes. anything i can do?
  9. R

    combi course

    I have been reading about a combi fault finding course in some of the trade mags. No doubt some of you will know which one im on about. Is it worth doing? I am newly qualified and no very little about fault finding?
  10. R

    no drain off valve

    ha ha scatman. I know im thick but exactly what is a bung.is it a cork or what
  11. R

    no drain off valve

    with what do you bung cold feed?
  12. R

    removing old olives?

    saw through olive at 45 degree angle till you can insert a small flat bit screwdriver into slot you have cut. twist screwdriver and bobs your uncle
  13. R

    Replacing radiator pipe

    paul, can you elaborate on what you said about causing water to hang in suspension? first time i've heard of this. would you have to close down all upstairs rads? i would have thought that when you cut into pipe you would have a flood of biblical proportions. not that i doubt what your saying...
  14. R

    New Boiler Recommendations

    what are viessmans like?
  15. R

    bbu fire without boiler?

    I have a baxi bermuda back boiler and am considering installing a combi. Can I leave back boiler in place and just use the fire? I will of course be disconnecting bbu flow and return pipes etc from new combi cicuit. If it can be left in place can gas supply to back boiler be isolated leaving...
  16. R

    imperial to metric

    I have been trying to find somewhere that stocks fittings to get from 3/8" copper to 15mm copper. Also 1/2"" to 15mm. Preferably compression fittings. Have tried the usual Plumbcentre, crosslings and BES but to no avail?
  17. R

    corgi reg

    assuming you had ccn1 etc, how much does it cost for corgi registration?
  18. R

    sealing cast iron toilet waste

    I have a toilet which discharges into a cast iron waste pipe. I have tried various silicon sealants to seal toilet waste but I always end up with a slight weep after a few weeks. Because of work involved/cost etc am unable to do away with iron waste. Also not able to connect plastic waste...
  19. R

    no heating till dhw satisfied?

    thanks for that. is 120 about right for cylinder stat?
  20. R

    no heating till dhw satisfied?

    i have what i believe is a y plan fully pumped system with a baxi bermuda back boiler. all controls ie programmer, room stat, cylinder stat and diverter valve are honeywell. programmer fairly new but others old, metal covers on cylinder stat and diverter valve. problem is this-if i switch...