    whats the difference between...

    I know what 3 way/diverter/mid-position valves are with the motorised heads on but I am wondering about the diverter valves that contain a diaphragm and what the obvious differences are as to their use? (apart from looks) I have read about how they work and understand this but what, when, where...
  2. D

    PRV and TMV help please

    So about 0.000001 bar. I can pi55 better than that. :wink: if the pipework were adjusted so the tmv was near the sink this would give approx 2 meters, would this provide a better head so to speak as already mentioned the cold is built into the heater so surely this cant be adjusted?
  3. D

    PRV and TMV help please

    It doesn't matter where the TMV is in relation to the heater, it's the height of the tank filling the heater that determines the head of pressure. ah right..the unit has the cold feed tank build into the top of it.
  4. D

    PRV and TMV help please

    guys, looking round the net I have thought about something and would like a genius to let me know. The TMV is directly under the water heater so practically no head :lol: the heater outlet has 90degree bend then about 4 inches of 22mm then straight into TMV. This is then met with the...
  5. D

    PRV and TMV help please

    Plumbing gods, Today I replaced a faulty PRV with a one from screwfix it is this one http://www.screwfix.com/p/prv-with-gauge-15-x-22mm/41943 went on a doddle however the pressure gauge is not reading? There is a TMV fitted after it and I noticed that after you draw off some water...
  6. D

    Electric Wiring behind plasterboard / other wall types

    get something like this http://uk.rs-online.com/web/p/cable-metal-stud-detectors/0418369/ you can get cheaper ones but i found them to be ineffective. The one above i believe to be very good
  7. D

    My Shower is causing my RCCB to trip...please help!

    hey, Yes get yourself a multimeter but dont get the cheapy things from wilko's or asda etc try get the best you can afford from somewhere reputable. And in the future it will always be handy to have hmm at £57 for an element you could be looking at a whole new shower nearly for that price...
  8. D

    My Shower is causing my RCCB to trip...please help!

    hey, you could check the resistance of the element if you can get into the shower and onto the terminals with a meter (power off obviously) a decent 8.5kW element should give around 6.22/6.77ohms if im not mistaken depending on your voltage might narrow it down a bit for you
  9. D

    Replacing existing single outside light with THREE

    sorry to jump in here..... how would you get round if somebody wanted outside lights all from same switch but did not want any external cabling/conduit etc inbetween fittings. As you cant run a cable down an internal and drill through as it aint within zones? cheers
  10. D

    electrical nvq

    http://www.cityandguilds.com/48210.html?search_term=2356 on here it says last registration is july 2012?
  11. D

    back boiler

    Will check this out tomorrow morning when I think it will be it's coldest. I will check the temps of the pipes also. If the coil is heavily scaled I'm assuming this would affect the heat transfer. I will try take some photos of everything also as they say a pic is worth a 1000 words :)
  12. D

    back boiler

    There is a pump under the floor boards downstairs which I believe is for the upstairs rads as once this packed in and rads did not work. Would there be another pump anywhere that may assist in the circulation?
  13. D

    back boiler

    cant see anything like that on it.
  14. D

    back boiler

    hey guys, it is a "Elson Double Fed indirect hot water tank" sticker on the side could only do magnet trick on about 3 foot of pipe work as it is unaccessible throughout the rest. Nothing happened when I tried. however when set to HW only both the flow and return pipes are untouchable...
  15. D

    back boiler

    genius!! I shall take all on board and get working it all out. Might have trouble with the magnet trick though as most the pipework is concealed :( but will see what happens
  16. D

    back boiler

    OK will check small tank. This small tank is attached to the big tank that holds the hot water if this makes any difference? This also may sound daft but if it relies on gravity then how does the hot water get up into the loft?
  17. D

    back boiler

    hot water tank is in the loft and is from what I can tell heated by the boiler circuit, there is no heating element or thermostat on this tank. I assume this heating is pumped up to the tank to warm it up but the produced hot water is gravity down to the bathroom which is on the ground floor...
  18. D

    back boiler

    guys, anybody know how long it would take a back boiler to heat enough water for a hot bath? I know there maybe many variables but I'm looking at 5 hours here and it not even hot hot if you get my drift :? would having the heating on make a major difference also? as always, many thanks
  19. D

    solder fittings

    guys, im not very experienced with this but have done it a couple of times. today though i was using yorkshire fittings and when heating i could see the ring of solder coming through but I was trying to add just a little extra from my reel but the reel would not melt? Little confused here as...
  20. D

    Compression TRV on plastic

    ok thanks again for that when i check the pipe is the brand easy to identify. Im assuming there will be many different brands therefore many different inserts and possibly difficult to find exact match I hate plastic already :(