    Worcester Bosch Greenstar Heatslave Programmer Fault?

    Sorry I have to Agree, Worcester Bosch used to make brilliant boiler....then they must have been taken over by a muppet!!!, sorry If I offend the Worcester Bosch Group, but really A down firing burner!!! that's prehistoric technology (boiler shuts off...HEAT RISES)!!! back into the burner, then...
  2. djsarge1973

    Intermittent problem with Grant Vortex boiler

    Hey Dave..Is this a new installation or just a new boiler?, & I'll be in lincolnshire next week so if your not sure I can come & have a look, also if it was a boiler swap (1 in 1 out) was the old system gravity fed (small tank in loft) then swapped over to pressurised system?
  3. djsarge1973

    Firebird boiler - Problem firing

    Ash.... if your having to "trip" the overheat thermostat I'd be inclined to look at the circulation pump.... if the boiler is running for 10 mins then shutting off...& your hitting the "overheat thermostat"...then it's water problems..... If your hitting the red lock out on the burner then...
  4. djsarge1973

    oil boiler

    perhaps some pictures of the boiler...& of the burner then we'll be able to tell you
  5. djsarge1973

    heatslave 12/14

    more info required, then might be able to help
  6. djsarge1973

    Intermittent problem with Grant Vortex boiler

    Where abouts are you I have all the grant manuals...& I will probably be able to help...you say the boiler is 2 years old...does it have the red l.e.d warning lights on the front (DHW pump, CH pump)etc, let me know
  7. djsarge1973

    Worcester Danesmoor oil Boiler

    May not be the Oil pump, could be Motor, but if it is the Oil Pump, then when you put a new one on get the tank dipped for water..other wise you'll be replacing the oil pump again!!!!!! if it's a B9 burner then it should be a Danfoss Oil pump, there are 4 allen screws (one on each corner) take...
  8. djsarge1973

    No oil coming to boiler

    Physically check the Oil Level...NEVER look just at the sight tube...as Oil delivery people LOVE to turn them off ( I thinks it's so they can charge more for an emergency call out)!!!!!, also you didn't say if the Oil line is copper? copper coated in plastic, steel?.... with more info might be...
  9. djsarge1973

    Oil filter - central heating

    have you got any of the old Nozzles?..look at the filters on the nozzle..are they discoloured?, has the tank been dipped for water?...yes the tank is currently illegal, but if installed before 2005, then it was current, an 11mm spanner will undo the bottom nut, it looks like a crosland filter...
  10. djsarge1973

    faulty grant combi outdoor 90 v3

    if you need help I can help out have all of the manuals for Grant....so you can get in touch with me I'l be able to help..or might be able to get an engineer down there to you
  11. djsarge1973

    trianco eurostar 100/125 condensing oil fired boiler

    Am in east Sussex Cold Girl, so if you want an honest opinion would be more than willing to help out
  12. djsarge1973

    Chipped bath

    chipped baths really do need re enamelling I can recommend a company based in East sussex, as I have used them
Back