    Radiator pipework - how to get a neat finish

    If the pipes were just too far apart, rad extension bars can be fitted too the rad and then the valve onto them, work really well.. but if the pipes are too far back to the wall then they wont work, can they get back under the floor, and send 10mm pipe up instead, get a much neater sweeping bend...
  2. D

    15mm from combi to 22mm?

    just take 15mm to the bath hot and cold, and shower, it will be fine.
  3. D

    Cold rad

    Most likely sludge in your rad if its cold at the bottom in the middle, are any other of ur rads similar to this ? try balancing the system if not take the rad of and run a hosepipe through it, if still nothing try a powerflush.
  4. D

    Compression Joints

    Are you sure you havnt kinked the flexi ? also undo the flexi and check there is no cr@p been flushed into the hose, these can sometimes have quite narror bores.
  5. D

    Compression Joints

    Not so much a disaster so would of been better posting in plumbing and heating, But just undo your fittings again and apply a couple of turns of PTFE on the olives then retighten, should solve your problem.
  6. D

    How am i still alive ???

    He says it was my fault as he said " i'd seen him cut the wires' a good few hours ago ! so i suppose i should assume that hes left them bare and live rather than safely isolated ! this guys only a joiner and is always doing dodgy things like this, he doesnt care to health and safety, all hes...
  7. D

    How am i still alive ???

    Right well today, in a storage cupboard between two flats, on a pair of metal step ladders one arm resting on a cast iron soil pipe, looking through a hole with a small penlight plastic torch.. WHEN the torch touched a bare live wire which my boss had left exposed ( i know, what a d**k, i had a...
  8. D

    More radiator problems

    You will need to balance your other rads, go around to your other radiators which are nice and hot and shut the lockshield right down then open up just a couple of turns, do this on all your other rads and see if your 2 cold rads start to get hot.
  9. D

    Shower screen trouble, help please.

    Right here goes, i have fitted quite a few shower screens before, but the one in question is a tc hinged shower screen, it is leaking from the lower hinge point where there is a small 1mm gap around the hinge as sort of clearance for the screen to swing, but water is getting into that gap from...
  10. D

    Pressure relief pipework

    No you can not use plastic speedfit fittings for this it must be solderd or compression fittings and yes it must turn back down the wall as to prevent it firing straight out the wall onto someone walking past.
  11. D

    Boiler problem or pipework problem? Help

    Have you simply tried balancing the system properly ?