  1. G

    ID this Baxi?

    NRV is on the heating side
  2. G

    Preparation for glue weld PVC waste pipe

    sandpaper would be fine but make sure you clean it with a solvent cleaner otherwise glue wont stick because of the small dust particles,
  3. G

    Motorised Vavle and low voltage to boiler

    i would go along lines of neutral fault L to E + L to N 230-240V
  4. G

    Intermittent Central Heating

    when you remove the screw from the pump head that is the shaft that is spinning you need to remove the head to see the impellor it may have come off the shaft
  5. G

    Intermittent Central Heating

    i have come across the impellor on the pump coming loose and intermittently working also they sometimes shear off completely valve pump off and remove 4 allen bolts remove pump head, may take a clout with the hammer and inspect the impellor
  6. G

    service prices

    please let me know how much you charge or have been charged for a gas appliance service/landlords time taken and location in country
  7. G

    warm hot water

    when you turn it up can you hear a click from the thermostat
  8. G

    7 day programmable stat

    that would work fine
  9. G

    diverter valve replacement

    if you have never done one dont attempt it there a pig and u will have the boiler in 1000 pieces and start crying
  10. G

    Wter greenstar ri, HELP keeps cutting out tried everything

    is it open there will be a little silver lever on one end of it, does it move freely from side to side
  11. G

    Wter greenstar ri, HELP keeps cutting out tried everything

    RI doesnt have a diverter its a system boiler. zone valve will prob be a silver box on the pipework
  12. G

    Gas in Lancashire

    strange question i think most village centers have mains gas these days its usually the old or outskirt properties that dont. Ilived in tarleton it had gas but we didnt cost of cutting into main was silly,
  13. G

    Agile Re worcester 9.24

    if you were familiar with this boiler you would be aware that the pressure switch is not located in the combustion chamber but it is located next to the pcb, Do you think i would tell a DIYer to remove combustion chamber or play with any gas related parts, if he buggers up the APS what will...
  14. G

    Vaillant ecotecplus 624 - heating not working

    hell you are unlucky works every time for me never failed unless gears slip then yes new head
  15. G

    broken boiler

    it needs an engineer its something beyond the DIYer
  16. G

    broken boiler

    f28 is numerous faults but basically no gas, fauly lead, gas valve, are you on card meter?
  17. G

    Worcester Heatslave 20/25 Oil, Spark but not Flame

    hmmmm i hope it doesnt soot up now :lol: