Search results

  1. P

    How a combi boiler works?

    Joe Mod 14 has you 8)
  2. P

    Oso direct boiler question

    Is there a timeclock controlling the system. They really should be set up so the cylinder heats up overnight on economy 7 and the boost is just for extra hot water when required. However I have seen a lot fitted in flats where no one has bothered to install an economy 7 meter hence it's...
  3. P

    ideal isar boiler honey well thermostat question

    tell that to the bloke who's detached house I went to had 18 separate splits in pipework on the central heating system, 3 burst rads, two bust toilet ball valves and 3 splits on flexi hoses to basins (and a partridge in a pear tree!) insurance left him dangling in winter for about 6 weeks...
  4. P

    Grundfos CH pump won't stop

    Danfoss HPA2 Auto setting means the valve operates via the external controls. Sliding the silver level across it slots behind a little catch in the black plastic which is manual position. In manual it allows the valve to be open and will fire the pump and boiler ignoring external controls...
  5. P

    Grundfos CH pump won't stop

    C means demand the boiler is registering demand. Likely either one of the microswitches on the hot water or heating valves are stuck on or the valve is in manual position. Check with the silver lever on the side of either valves
  6. P

    baxi solo 30 pfl cuts out after 10 mins then tries to ignite

    If it's the OP i'll put my tin hat on and sleep in the cellar. He may live close by :roll:
  7. P

    capping of hot and cold supply to bathroom

    and wear ear plugs :wink:
  8. P

    ideal isar boiler honey well thermostat question

    A little bit of gas is way less expensive than a burst with all the damage it can bring.
  9. P

    capping of hot and cold supply to bathroom

    I'd cut the pipes and fit isolation valves. That way any problems are easily isolated and saves messing about
  10. P

    Gas Fire Unidentifiable

    Could be a focal point.
  11. P

    New Combi Boiler Installation

    I'd stick with the Vaillant
  12. P

    DHW sensor fault on boiler display

    You must be suggesting the water board flush the mains then :roll:
  13. P

    No hot water. Is this just a 3 way valve problem?

    you will not have a 3-way valve on a gravity system. firstly Is there water in the central heating F+E tank (the smaller one)
  14. P

    Help replacing Honeywell thermostat with a Salus RT300 RF

    needs both. permanent live keeps power to the receiver all the time while you need the switch live to tell the boiler to come on. Though with a combi boiler you could do away with the timer altogether providing your wireless part of the stat is programmable. i.e you can set times aswell as...
  15. P

    Help replacing Honeywell thermostat with a Salus RT300 RF

    http://www.diynot.com/forums/plumbing/replacing-honeywell-t40t6360b-thermostat-for-wireless-stat.351383/ you have the same issue as this thread. You need a permanent live.
  16. P

    Heating Controls

    :roll: 2-port valve wire call from stat/timer to brown on valve
  17. P

    stainless cylinder reducing to 22mm

    put a balancing valve on the return to restrict the flow