  1. Untitled

    Untitled

  2. biasi

    biasi

  3. P

    Plumber damaged boiler exterior, what do do?

    people actually visit and listen to your inane drawl. It's a plastic flap, get a life, move on :roll:
  4. P

    Glow Worm 30 Si Fault F2 - Fixed

    Why pay for BG then if you are over qualified on your own boiler ?? :roll:
  5. P

    glowworm flexicom 30 cx problem

    and Morrisons value eggs?
  6. P

    Replacing honeywell T40(T6360B) thermostat for wireless stat

    Your timer in the airing compartment will only send power to your current roomstat when the heating is switched on via the timer. You are proposing replacing the current roomstat with a wireless roomstat. The wireless roomstat can be placed anywhere however the receiver unit requires a...
  7. P

    Glow Worm 30 Si Fault F2 - Fixed

    You shouldn't be advising repairs to gas safety controls especially with insulation tape
  8. P

    Replacing honeywell T40(T6360B) thermostat for wireless stat

    Unless it comes via a clock or other external control before it. What is it controlling?? If it has say a clock fitted before every time the clock switches in and out of it's time periods power is going to be cut to the receiver
  9. P

    Replacing honeywell T40(T6360B) thermostat for wireless stat

    your current stat is common and switch live. The receiver box needs a perm live and neutral. you can link Live to A but it will need rejigging at the other end and B is calling (yellow)
  10. P

    Central heating vent pipe - continual flow of hot water

    not really but it's your house, besides it will be likely it has been doing it for a while so a couple more days or so isn't going to make much difference. extending the vent pipe is papering over the cracks. the magnet test is not definitive but it indicates the air sep and surrounding...
  11. P

    worcester 37cdi loosing pressure

    a fault with the pressure vessel would be indicated when the boiler is running, i.e when it is heating up the pressure rising to 3bar at which point the PRV operates and you would find water coming out of your discharge pipe. Sounds like a leak under the floor. uninsualted copper in concrete...
  12. P

    Central heating vent pipe - continual flow of hot water

    could be restricted around that air separator. You could try running a magnet over it see if it attracts itself to the pipework
  13. P

    Central heating vent pipe - continual flow of hot water

    a picture of your pump cold feed vent pipework may be helpful to make sure it is piped up correctly
  14. P

    Central heating vent pipe - continual flow of hot water

    possibly a blocked/restricted cold feed
  15. P

    potterton 40e main burner not coming on

    make sure you bleed system without the pump running as it can drag air in.
  16. P

    potterton 40e main burner not coming on

    turn all the other rads off so it's just the affected one open. If it's air locked to that rad it should clear it
  17. P

    Temperature sensor

    If it's a wet pocket sensor it would depend on the quality of the water in the system
  18. P

    Ideal Isar boiler H 3 problem

    that makes sense