    BAXI 105HE CONDENSING BOILER

    pressurise boiler to 1.5bar, turn it off (power) then far left and far right black isolators quarter turn to isolate the heating circuit. If the pressure doesn't drop over the usual period the leak is on the heating system. If it does it's the boiler.
  2. P

    BAXI 105HE CONDENSING BOILER

    left to right HTG 22mm DHW out 15mm Gas 22mm CW inlet 15mm HTG 22mm valves are chrome and either have plastic isolators or square chrome isolators Isolate both heating valves with the boiler at 1.5 bar. If it still goes down leak is on boiler
  3. P

    Ideal Icos DIY PCB Replacement?

    Tony Glazier and D Hailsham are the only guys that know what they are talking about.
  4. P

    Ideal Icos DIY PCB Replacement?

    Damn!! The secret of the vacuum operated sensor is out
  5. P

    Ideal Icos DIY PCB Replacement?

    Excellent news I will cancel my gas safe registration first thing and ask for a full refund My favourite job ever is swapping air pressure switches on boilers operating a zero governor :roll:
  6. P

    baxi duotec 28 he error code E119

    If pressure is above 1 bar and it's still registering this fault then it is likely either a faulty water pressure sensor or dirt in the sensor not allowing it to read the correct pressure. Have you tried increasing the pressure to 1.5 bar to see if this activates? I have been to one...
  7. P

    Pump Obsolete - any recommendations

    If it's a British Gas pump then it's probably the Myson type. You could try a Grundfos head but like you say pump is obsolete now
  8. P

    Pump Obsolete - any recommendations

    A picture of the pump would be helpful. British gas used to use myson pumps which had a black plastic nut over the impellor then they changed to a Grundfos pump. Really a standard pump head off a Grundfos 15/60 may fit.
  9. P

    Worcester 24i Junior RSF, high pressure problem

    Check for a blockage in the pipe to the expansion vessel. Did your pressurise the vessel with an open end (i.e drain cock open)
  10. P

    Potterton Puma 80e Full Sequence Board & Gas Valve

    Agreed. I only put that cause I found out the hard way
  11. P

    Potterton Puma 80e Full Sequence Board & Gas Valve

    Various things could fry the full sequence board. If it has fried it may have been advisable to test components and have a look round the boiler for possible issues before putting a new board straight on.
  12. P

    Ideal isar HE 30 +programmer XF 2008

    As soon as you take front cover off the boiler the diverter valve is in front of you on the left hand side towards the bottom. It's a square box. It will be evident if it's the grey or red topped diverter valve head. They are not interchangeable. If you see the colour of the valve head you...
  13. Untitled

    Untitled

  14. Untitled

    Untitled

  15. glowworm

    glowworm

  16. P

    Ideal isar HE 30 +programmer XF 2008

    If there is power into the boiler and to the pcb but there is no display on the user controls then it's PCB which has failed. It is unlikely that the user controls have failed. HE and LE indicate pcb error as does no display. I have repaired more of these than I can remember with this fault...
  17. Untitled

    Untitled

  18. Untitled

    Untitled

  19. ssf

    ssf

  20. P

    PRV and TMV help please

    10m head height would give you about 1bar. 1m head height would only register about 0.1bar which on a gauge would probably not be visible