    powermax 140 boiler

    You can try adjusting the blending valve to see if this improves it by removing the cap, loosening the backnut then turning the square valve head with an adjustable spanner failing this it's more than likely a new one required.
  2. P

    potterton 24he problem with hot water water

    Likely to be an issue with the diverter valve passing
  3. P

    Rainwater diverter to water butt

    A question we would all like to know the answer to. :?
  4. P

    Hot water not turning off from boiler

    Likely your motor has seized in the valve. If you try to push the manual lever over on the valve what happens? A replacement motor is about £12
  5. P

    Sime super 105 mk2 pressure.

    If the boiler is continually at 3bar whether it is operating or not then either the filling loop is passing or the DHW heat exchanger is pinholed causing mains water to mix with central heating water
  6. P

    Vaillant hot water problem

    It's likely your DHW flow switch is stuck on. Try tracing the wires to it and removing one and then see if your boiler still fires
  7. P

    Electric Boiler for domestic only (not C/H)

    Price of copper cylinders/tank/pipework it's probably like for like with a vented system. Plus there is no need to have an extra tank/lagging/overflow etc etc. Unless however the mains pressure is poor
  8. P

    Electric Boiler for domestic only (not C/H)

    Depending on mains pressure your best option is a direct unvented cylinder. You would get hot water at mains pressure.
  9. P

    Removed upstairs rad now all are cold

    Depends on the pipework layout. They may have gone straight in and out through the rad have you tried putting it back on to see what happens?
  10. P

    Flue installed near to Vent

    Has the neighbour installed the appliance himself or has someone done it on his behalf?? Your neighbour might have paid for the job to be done in which case he may have presumed it was all above board. If he has installed it himself and is GSR he should have known better. If he has...
  11. P

    Flue installed near to Vent

    A photo of your situation may help to clarify it for you
  12. P

    Kingfisher boiling over

    You could try testing the thermistor from the PCB 25C 1.2MOhms down to 100KOhms at Temperature (82C)
  13. P

    Kingfisher boiling over

    Presume OP means the Kingfisher MF fan flued floor stander with boiler thermistor (two yellow wires to PCB).
  14. P

    IDEAL EVO HE - Bang on ignition

    agreed agreed. That is a separate issue which needs rectifying but not by a DIYer
  15. P

    IDEAL EVO HE - Bang on ignition

    Yep. very sensitive to dripping taps these boilers. The sensor in the cold inlet registers on a slight change in temp and fires the boiler up
  16. P

    lukewarm bath tap

    Likely it's the flow rate through the bath tap have you tried reducing the speed of the flow though the tap? what size is the boiler ?
  17. P

    Can I

    If it's already done there is nothing stopping you from taking the boiler off the wall. Turn water and electrics of first mind :lol:
  18. P

    Powermax 155x - newbie question?

    Try a link L1 to 27
  19. P

    Can I

    No. The gas needs disconnecting from the supply from a RGI.