  1. clarkerothwell

    Janus Circulator problem

    hi, cheers, there is no cylinder, its a square type tank with a small cistern tank attached to the side, and its direct, not in-direct, so only the one cold feed tank. its not been drained for years, but the return pipe is below the flow, so any air would be in the higher pipe from the janus...
  2. clarkerothwell

    Janus Circulator problem

    Janus circulator, attached to Johnson and starley wau. Hotwater is only luke warm, heater is firing up and flow pipe gets boiling hot, but htr keeps cutting on / off, return pipe never gets hot... The storage tank is a direct one (not sure of the make,but its a square one with the cistern...
  3. clarkerothwell

    Vokera Linea 28 fault with hot water

    will do in future , cheers, and thanks again pablo.
  4. clarkerothwell

    VOKERA LINEA 28 EXPERT REQ !!!

    CORRECT !!! Yes. you are spot on, changed the board and it sorted it, after i was mis informed it was the non return valve, which was fine. The domestic thermisister was faulty too, so your totaly bang on. Thanks for the advice.
  5. clarkerothwell

    Vokera Linea 28 fault with hot water

    been informed its the non return valve in the right hand manifold of the domestic heat exch - bloecked or broken, part number - 2908 in vokera manual
  6. clarkerothwell

    VOKERA LINEA 28 EXPERT REQ !!!

    been informed its the non return valve in the right hand manifold of the domestic heat exch - bloecked or broken, part number - 2908 in vokera manual.
  7. clarkerothwell

    Vokera Linea Problem

    THANKS, one i'll never forget !! was thinking it was the board! System water is quite dirty, going to fit a magna clean, and offer to flush system too. sorry for hijacking post, but its a few years old, and was only one i could find with exactly same fault and no body would answer mine on...
  8. clarkerothwell

    Vokera Linea Problem

    wow, really? how does that keep water to a constant 42 degs?? is this a common fault on the linea then ?? Will i have to replace or clean? PS thanks for the reply, much appreciated !
  9. clarkerothwell

    VOKERA LINEA 28 EXPERT REQ !!!

    Constantly running at 42 degs on domestic hot water Boiler fires on high rate cuts to low rate, water remains at 42 degs never cuts out Both thermisters changed New Plate h/exch fitted Not passing down diverter to htg Water tempt Dial set to max - not broken spindle ANYBODY...
  10. clarkerothwell

    Vokera Linea Problem

    i'm having EXACTLY the same problem !! ANYBODY KNOW WHAT THIS IS PLEASE HELP!!!
  11. clarkerothwell

    Vokera Linea 28 fault with hot water

    i thought it was typical linea dom ht exh blocked, but it wasnt cutting out, but i removed and flushed anyway, did get some debri out but only usual amount. I borrowed new one and exh but still same !
  12. clarkerothwell

    Vokera Linea 28 fault with hot water

    eh up DP, cheers for reply mate. Only what i did (i'm gas safe reg), diverter valve service kit fitted about a year ago.
  13. clarkerothwell

    Vokera Linea 28 fault with hot water

    hi, searched and couldnt find anything similar to this fault - Heating works fine When demand for hot water boiler fires ok to full gas rate (10mb) then drops after about 3 secs to low rate and stays there, doesnt cut out ever, water runs at a constant 42 degs. Never gets any hotter and...
  14. clarkerothwell

    vauxhall vivaro nightmare!!!

    mine doing exactly the same - also 53 plate, 99,000 miles. Had new turbo, and air flow sensor !! still the same PLEASE has anybody got a clue what this is!!!!!
  15. clarkerothwell

    Ferroili sigma 40 - 60

    boiler cutting out from overheating (prob heat exchanger slighly scaled or blocked up - boiler 7 years old) and noticed prob occurs when ext controls are satisfied, boiler gurgles and very nosiey then locks out. Noticed pump not wired into circuit board and no permanent live, so corrected...
  16. clarkerothwell

    boiler cuts out after 2 hours or so

    PUMP OVER RUN - Has the pump been wired to the boiler orto the control center?? Pump needs to run after boiler shuts down to stop over heating, had this problam with a relatives boiler.
  17. clarkerothwell

    Pro - Combi 85 HE

    these boilers are same as vokera compact 25HE, Re badged as pro combi's, very good cheap boiler with vokera after sales back up, they may have slightl inferior parts fitted than original vokera ones? But it is a band B boiler NOT a sedbuk A.
  18. clarkerothwell

    New boiler price ? which boiler

    excellent price, gas board would be about 3 grand. Good boiler too, must be light on work, i quote 1800 - 2000 and win almost every quote.
  19. clarkerothwell

    worscter bosch 28i problem

    yeah, it was time clock faulty, thanks for all your help, great site.
  20. clarkerothwell

    worscter bosch 28i problem

    about five year old, condensate pipe was blocked with ice, cleared that and boiler now works ok, apart from no heating now?? Was nothing working before when condensate blocked with ice, but now hot water works ok, but not heating, all external controls set to calling, but nothing, boiler not...