  1. SparkyNinja

    Antsy attitudes

    I have to back up BAS 100% on this post, from experience.
  2. SparkyNinja

    Double decker / Narrow consumer units

    There are 9 ways in total. Maybe 2 x smaller boards is the option to take. Existing 100A main switch is in place already (surprisingly) Many thanks.
  3. SparkyNinja

    Double decker / Narrow consumer units

    Does anyone no a brand of consumer unit that accomodates installation in narrow areas. Doesn't have to be too narrow, but a standard 17th edition board wouldn't suffice and RCBO's are a little out of my clients budget. I remember RF had posted an image of one a while back (I think it was RF)...
  4. SparkyNinja

    PAT - Rip Off

    PAT = Portable appliance TESTING or PALAV = Portable appliance looking at VISUALLY ..........and making a vague conception and charge small amounts of money which recks our industry because you are too tight or worried to get the necessary paperwork or equipment...
  5. SparkyNinja

    Do I need a new Consumer Unit?

    Necessary - No, not if any work you have done can be accomodated with what you have existing. Advisable - No, not if any work you have done can be accomodated with what you have existing. Is replacing a consumer a nice little money maker for electricians if they don't do it...
  6. SparkyNinja

    Lighting in single core cable

    Do you mean 2 plate wiring?
  7. SparkyNinja

    2D lamp flicker

    How long dast the starting flicker actually last for, on average?
  8. SparkyNinja

    Change of scheme within NICEIC?

    My thoughts exactly.. Email sent 8)
  9. SparkyNinja

    Change of scheme within NICEIC?

    Hey guys, quick question for those with NICEIC enrolment. (If you don't have it, but can help also, then cheers). I am having to change my scheme from Domestic Installer to Approved contractor to meet the demands of some clients. I was planning on having the Periodic Inspection Reporting...
  10. SparkyNinja

    Certificate for temporary generator installation?

    Change a couple of headings like 'venue' and 'event' and BAM! I gotta a cert that has a half for the existing installation (where the existing bonding etc needs to be recorded), and half a cert with details of the kVA, phases, are additional earth electrodes deployed etc.. if yes, give details...
  11. SparkyNinja

    Certificate for temporary generator installation?

    Scratch that. I think I have found something by going down the BS7909: 2008 route :wink:
  12. SparkyNinja

    Certificate for temporary generator installation?

    Hey all, wonder if you can help? Had 2 phase go down on a distribution cable at one of the schools I regularly work at yesterday and the result was needing to get a 115kva generator in situ temporarily. The cable had been jointed somewhere and it appears that that has failed. (0.0Mohms across...
  13. SparkyNinja

    Can't find 'approved contractor' on LABC, what to do?

    Designation = Wylex :?: Also, isn't it good how all the 11 RCBO's trip in exactly the same time.
  14. SparkyNinja

    Quick PAT question.

    What is the yellow tape there for? Was the a PAT specific company, paid by the unit kinda stuff?
  15. SparkyNinja

    help with replacing a 2gang switch

    If it is a 2 gang switch it could be 2xswitch lines and one feed. Otherwise what is the other switch for?
  16. SparkyNinja

    New downlights - flickering

    You may find that the longevity of your dimmer will be compromised, especially if you used gu10's as you are supposed to consider the derating, unless the dimmers are iQ. But go and check the connections to that fitting
  17. SparkyNinja

    hidden cable depth clarification

    Is an RCD present? What is the use of this spur intended for?
  18. SparkyNinja

    hidden cable depth clarification

    Spur from the existing spur? Or spur from the ring? The cable will have to be >50mm in the wall unless the circuit is protected by an RCD, or if you were to use a cable with an earthed sheathing of some kind. The fact that the socket is twin or single is irrelevant
  19. SparkyNinja

    so who wants to be a domestic electrician?

    I withdraw everything I said because I AM AN IDIOT!
  20. SparkyNinja

    Can't find 'approved contractor' on LABC, what to do?

    Fire away, if you want me to re-up bigger copies let me know :wink: Response from the NICEIC this morning is that they want all of the information I have on the company. The big concern is that the company is a housing association service and so they probably pull this off every...