  1. W

    noisy isar he 35

    Only noise i have heard when condensate blocked is a bubbling noise within heat ex not as you described
  2. W

    ideal isar he35 d.h.w. probs

    When system is cold turn on hot tap & feel 22mm pipes on lhs of boiler if they get hot your diverter valve is passing. Make sure you get the correct cartridge ie honeywell (which fits a lot of boilers) if it is a red actuator you will need the unique ideal cartridge (VF)
  3. W

    vulcan boilers

    I'm glad i dont pay your gas bill
  4. W

    vailiant boiler keeps building up pressure

    Or plate heat ex passing due to high water pressure
  5. W

    power flushing

    First of all do you need one? Best check is to remove a small radiator & empty water into a bucket (not a black one) if water is clean you generally don't need a flush
  6. W

    noisy isar he 35

    Call an engineer asap & don't use until he has called as a common fault on this is the flue gasket being displaced which normally makes that kind of noise also get him to check insulation panels & fit earth pin kit
  7. W

    Boxer C28 - Heating Close To Boiler

    Pump is inside boiler case
  8. W

    Heatline C24 Boiler no hot water.

    My only advice is save lots of money cos parts are very expensive for some reason
  9. W

    Radiators cold unless hot water is on

    The icos ain't a combi if you have a 3 port valve it is most likely that the end switch has failed so new valve reqd (or head if possible)
  10. W

    DHW HE or DHW Thermister

    Phone ravenheat & ask for a dry pocket thermister (they are available) just connect wires & clip onto pipe between u/s thermister & o/h stat also change dhw thermister in usual way
  11. W

    Downstairs rads cool

    Pump not fast enough or blockage in system
  12. W

    baxi bermuda 552 back boiler

    Get him to clean pilot properly
  13. W

    HELP !!! have hot water but no central heating

    As i previously posted you need to turn on dhw on clock & turn up cyl stat so you have a demand for hot water
  14. W

    Rotted isar

    This has become a mojor safety concern & ideal have re-designed the earth pin so it holds back insulation boards you have to remove burner to fit them
  15. W

    heat line vizo HELP

    I bet parts costs a fortune on these things
  16. W

    HELP !!! have hot water but no central heating

    Probably your motor in valve upstairs in airing cupboard.With a flamingo 50 you will most likely have a y-plan valve so as a temp measure turn on dhw turn cyl stat higher & lock valve to open position (small lever on side of valve) until motor replaced.Otherwise it could be relay on clock or...
  17. W

    Glow worm space saver Mk.II problems

    Probably pilot inj dirty or t/c lead which are only a few quid
  18. W

    Vokera Excell 80SP

    Easy just take 4 screws from front panel pull forward to let in air & try to see if it works. If so just clean fan heat ex & fan venturi
  19. W

    British Gas C1

    Boiler was made by worcester for b.g. If slow flash on c/htg neon it indicates ign lockout is gas supply on @ meter & valve under blr turned on if so could need a gas valve or electrodes
  20. W

    Glow-Worm Feulsaver MKII Boiler Clicking Off

    One of 3 parts probably 2 of them cheap valve mor costly but also more unlikely.Could also only need a good service to remove zinc oxide from h/ex