  1. W

    New Shower = Hot water entering Cold Water Tank - Help!

    Why are you reluctant to get him back when he has clearly piped it up wrong somehow
  2. W

    Heating comes on when hot water is turned on

    If you had a new diverter valve last year it may be that you have a dirty system & after your wife put on htg something has blocked the htg port allowing hot water to pass down to htg circuit. Try feeling pipes on div valve & check if lever on side hasn't inadvertently locked into the venting...
  3. W

    I've broken my Primatic Fortic cylinder?

    You will also need to convert system to fully pumped & if you seal it you will need to route a safety blow off pipe to outside & probably change rad valves
  4. W

    New/Old 3 port valve

    B for bath A for air AB from pump
  5. W

    Valliant Combi VCW Sine 18 T3 overheating

    Yes the ntc resister has a single purple lead.To test when htg is on remove lead & short it to something metal (trust me it won't cause any problem) if burner then goes out the ntc is faulty
  6. W

    New/Old 3 port valve

    You can still get 3/4" internal bsp 3 port valves all you do is remove adaptors or bushes from old valve when it is out & transfer to new one
  7. W

    HOT WATER OVERFLOWING INTO EXPANSION TANK

    If on a fully pumped cross vented "h" system suspect the horizontal piece is blocked with magnetite (try placing a strong magnet on copper pipe). If so you must reconfigure pipework asap or your system will rot & rads will pinhole
  8. W

    Releasing excess system pressure through the PRV

    If you do release pressure from prv you will invariably have to clean seating or change it which is why a lot of makers are now putting the prv away & out of sight to remove temptation
  9. W

    potterton suprema 100 not firing up

    From what you say i would guess that the valve with floppy lever has actually opened but failed to operate end switch & the one you force open to fire boiler for 10 secs has a failed motor
  10. W

    Potterton Puma (Mind of its own)

    Boiler is thinking you have tap turned on either because the dhw microswitch is faulty or it is adjusted wrong
  11. W

    Boiler not heating water

    Check if there is a bleed cap on flow pipe to cylinder if so loosen it until water appears
  12. W

    Venturi v Thermostatic showers from a Combi boiler?

    I have a mira 415 combiforce with a vaillant ecomax 828/2 & works really well
  13. W

    Vokera 24e Hot water delay

    Sounds like poor pump performance or poor circulation through boiler
  14. W

    Anyone know these valves?

    Cut the spindle when they ain't looking
  15. W

    Is this allowed??

    Not at risk it is n.t.c.s.
  16. W

    Ravenheat RSF84 Works intermittantly

    Try changing thermister first
  17. W

    GLOWWORM MANUAL

    I had one about 25 years ago. Try manufacturers on the thinternet
  18. W

    Loss of Water Pressure Through Combi Boiler

    If we knew make of boiler it might help ie a lot of vokeras have a flow restrictor which will just need taking out
  19. W

    Ideal Isar HE30 PCB faulty again!! Need to rant

    Whoever fitted the replacement pcb should provide another one
  20. W

    Boiler Pressure

    Plate heat exchanger is passing internally