Search results

  1. W

    Is GP Sand the same as Building Sand?

    Hi, Is building sand the same as GP General Purpose Sand? This will be used for mixing mortar for a block wall. The builders merchants stock either GP (more gritty) or Plastering sand (smooth) in stock. Thanks
  2. W

    Should solid concrete blocks be moist before Laying them?

    I'm building a garden wall and have been told to ensure the solid concrete blocks are moist before laying. Is this best practice and does it ensure a better bond. For instance like when plastering a wall? Thanks. 😊
  3. W

    Garden wall advice please

    Hello, I'm going to build a garden wall which will be 12 metres long x 1.5 to 1.8 metres high x 215mm wide using 140x215x440mm solid concrete blocks. The wall will be tied into existing wall either end and was going to build double width pillars on the ends and maybe one in the middle for...
  4. W

    CCTV D1 resolution DVR help

    Hi I'm looking to purchase a DVR for a 4 camera CCTV home system. I would like the DVR to be capable of the following:- My preferred option would be D1 resolution on all 4 channels at 25FPS (real time) or alternatively 12FPS on all 4 channels. What reliable and good quality D1 DVR's...
  5. W

    Who makes these Ball Valves?

    Does anybody know who makes these Full Bore Ball Valves and if they are still available. I thought they were Yorkshire, however can't find them on there website, have they been replaced by the Pegler ones? Thanks
  6. W

    Full Bore Ball Valve or Isolation Valve for Basin & Toil

    Hello Just wondered which type of valve would be best to use for the basin (monobloc tap with flexi tails) and toilet in my bathroom. Is it okay to use a standard 15mm isolation valve with screwdriver quarter turn or is it best to use a 15mm quarter turn full bore ball valve to prevent any...
  7. W

    Halers / Collingwood H2 / EvoLED Dimmable Failure Question??

    Hello I've now fitted over 100 of these downlights (Halers / Collingwood H2 / EvoLED Dimmable Downlights) with no issues. However recently two have failed shortly after installation. Has anybody else experienced any failures or aware of any issues? I have sent an e-mail to supplier to...
  8. W

    Waste pipe advice for shower and basin please

    Hello I'm currently installing a new shower and basin. The drain pipe to the stack will be 2" (55mm) pipe which currently has a fall of 35mm over a 2.8 metre run with one swept bend an two 45 degree bends. Should I raise up the shower even further to increase the fall on the drain (is the...
  9. W

    1

    deleted
  10. W

    Indirect Hot Water Cylinder Help Please

    Hello I need to replace my existing un-vented indirect hot water cylinder. I'm looking for either a 250 or 300 litre capacity, which will be used with a Wilo booster pump fed from a 500 litre loft tank, due to the mains water pressure and flow being poor in my area. Can you recommend...
  11. W

    Boulter Camray 5 (95/130) System Boiler Wiring HELP

    Hi, I have a Boulter Camray 5 (95/130) System Boiler which will be connected to 3 x 2 port valves ( central heating rads / under floor heating circuit / hot water cylinder). With external programmer and thermostats etc. The OSMA UH1 control centre I'm using requires boiler enable...
Back
Top