  1. M

    strange potterton puma divertor valve ??

    Tony are you suggesting it may be stuck in mid position between the two ?? is there a quick fix or strraight replacement ??
  2. M

    strange potterton puma divertor valve ??

    Guys.. Didnt get much time to look much at this 1 but tenant advised radiators heat up when DHW is on... This is a potterton puma 80 e I didnt think this could happen with the wax capsule Puma divertor valves SO MAY need to investigate further?? anyone else had this ?? surely it can...
  3. M

    HOW TO REMOVE A PUMA DIVERTER VALVE ??

    my bahco's will be ok for gripping once I bend back the metal.. although i think for long term I'll get an offset spanner as the potterton guy mentioned, may save a little time.. Done a few of these already but was fortunate to get to the wax capsule and freed the grub screws on these but...
  4. M

    HOW TO REMOVE A PUMA DIVERTER VALVE ??

    cheers mate.. may do this till I get my hands on a 30mm and 32mm offset ring spanner take it youve had the same problems with the grub screws then !!!
  5. M

    HOW TO REMOVE A PUMA DIVERTER VALVE ??

    Guys. Having a bit of a problem replacing wax capsule diverter valves in Puma 80's.. Had a nightmare today as the grub screws on top were corrroded and stuck and couldnt disconnect from the back as its too tight for my grips. Anyway removed full section from the front with force but on...
  6. M

    BAXI COMBI 80E POOR HEAT AT RADS !! URGENT !!

    Looking for some help urgently guys. BAXI COMBI 80E .. Boiler fires on both CH AND HW all ok but on CH mode only reaches 50 oC and rads are warm but not hot enough. Tried thermisters and even swapped HW and CH but no change. resistance was ok also so ruled this out. Is the PCB faulty...
  7. M

    DHW CYLINDER CHANGEOVER HELP !!

    cheers mate appreciate the advise.... thank f*** someone knows this set up need to disconnect the towel rail then just leave the tails open at the boiler as there no need for for the use of the boiler apart from the towel rail and as there is already a radiator in the bathroom it aint doing...
  8. M

    DHW CYLINDER CHANGEOVER HELP !!

    what ive done meantime is linked the tails from the back boiler to stop the flow of water constantly dripping and its circulating round the old circuit but my thought were if the old solid fuel boiler was used it would kettle up. although it is linked to the DHW draw off and still has a way of...
  9. M

    DHW CYLINDER CHANGEOVER HELP !!

    more info.. the extra cold feed and return seemed to be connected to a towel rad in the bathroom, the DHW draw off was connected to the rad also coming back down from the loft. Strange as there was no coil or nothing and the draw off clearly passed through the towel rail... Ive looped the...
  10. M

    DHW CYLINDER CHANGEOVER HELP !!

    the cylinder was deffo indirect mate flow and retrnd were in 15mm and came in at the top, can clearly see the coil etc.. Im coming round to thinking that this 5th pipe and the tee of at the cold feed may have been to utilise the solid fuel fire when running but strange how the DHW DRAW OFF is...
  11. M

    DHW CYLINDER CHANGEOVER HELP !!

    I did mate and im still baffled its a really old cylinder like 2 thin cylinders joined together. for the life of me I cant understand the 5th pipe and the cold feed branching off its like it loops in a circuit and must be connected to the draw off somewhere. the flow and return are indirect...
  12. M

    DHW CYLINDER CHANGEOVER HELP !!

    Guys, started what I thought was an easy job of changing and moving an old cylinder and its became a nightmare.. think at 1 time this house had coal heating but new system had been put in and old cylinder left. right now thought it was simple FLOW & RETURN, COLD FEED AND HOT WATER DRAW OFF...
  13. M

    POTTERTON KINGFISHER MF

    AAAHHH got this bit now, seen this on a worcester before.... gas valve resistance was low blew the board twice before the engineer sussed it.. .. Luckilly this aint my problem as boiler still works and nothing blown.. still unsure on the PCB or thermistor though but go with the costs first ...
  14. M

    Baxi Bahama 100, a few issues

    the flow switches on these things are ****.. Ive had to replace loads even though potterton say you only need to clean.. another thing to apparently watch out for is the CH flow switches is somehow tied into the DHW flow also .. according to the helpline the DHW tells the boiler to fire and...
  15. M

    Hot water in expansion tank

    could be pumping over. check your pump speed, could also be a blockage but check pump speed first and turn down if required..
  16. M

    POTTERTON KINGFISHER MF

    guys went back to the boiler today, its a kingfisher 100 rs. as usual no fault on arrival but tenant advised no lights came on etc just no heating on demand. did notice that tat when I turned the temp control down the boiler would attempt to start then keep clicking on/off like the relay...
  17. M

    POTTERTON KINGFISHER MF

    Whats the common faults with these boilers ?? was at a callout today and tenant has to keep resetting, as usual wouldnt do it when I was there and he didnt know what lights were flashing etc ?? just wonder the usual faults ! :roll:
  18. M

    air in how wter/heating system

    system may also be corroded, if you need to keep bleeding rads its cause there no inhibiter in the system, wont cure the problem to add it but will help a lot and limit corrosion, had this problem in my last house, I flushed the system added sludge remover, drained 2 weeks later then added...
  19. M

    hot steam comes out of vent pipe

    yup sounds very much like a blocked dropped feed..
  20. M

    Radiator only hot at the top when bled

    sounds to me like its sludged up !!!