Search results

  1. M

    ideal isar diverter valves

    totally agree poor design and so common on these boilers, these things eat diverter valves and pcb's and it aint cheap to fix them.. looking at the mechanics of the valves, very cheap made and little in them, replaced every one so far but after looking inside and spraying and lubing it made me...
  2. M

    ideal isar diverter valves

    Guys, had 3 of these this week with rads constantly heating due to sticking diverter valve bodies, all 3 were with wilo head (plastic cartridge) has anyone tried just cleaning these and lubing ?? really cant see why they stick so easy and never actually tried just lubing and cleaning but...
  3. M

    where to sell unused parts ?

    seriously mate i'd rather throw it in the river than punt to chancers on ebay ! that gas valve cost a fortune at the time, we ended up ripping out every lynx electronic and replacing as they were too costly to fix ! they damn things eat pcbs !
  4. M

    where to sell unused parts ?

    it aint on ebay yet !!!
  5. M

    where to sell unused parts ?

    exactly mate, drives the prices down and therefore make it worthless to sell legit parts. I its a buyers market on there, the main thing i was looking to sell was the gas valve, the others not too fussed as they more than likely will come in handy but listed the valve once and cancelled the...
  6. M

    where to sell unused parts ?

    folks, have a few parts im never gonna use, stuff that was for a contract my company lost, sold a few bits on ebay but looking to see if anyone knows somewhere to sell back to as these parts will no longer be required !! got 1. 1 x potterton lynx electtronic gas valve 2. 1 x worcester...
  7. M

    OCEAN ALPHA CB24 HELP

    this one actually looked ok when I TOOK APART !! think the shaft must have been sticking and not making flow switch, the kit quickly fell apart when I opened up second time tho !!
  8. M

    OCEAN ALPHA CB24 HELP

    not wrong there mate but if I had the diagphram to change it would only have been the once, plus its for a mate so £30 for a kit compared to £130 for a DV, think i know what he would want !! thanks for your advise again guys !
  9. M

    OCEAN ALPHA CB24 HELP

    the diagphram change looks quite easy, remove pump, 4 screws and in, seems a lot easier than a full DV ?? unless the kit assy is a pain it looks quite straight forward !
  10. M

    OCEAN ALPHA CB24 HELP

    Paul from both comments above it would seem I refitted correctly first time, When i removed the diagphram it all came in 1 piece, held together and I cleaned and put back togehter and it leaked at the divertor valve ? strange as it didnt do this before ?? There was no real re assembly just...
  11. M

    OCEAN ALPHA CB24 HELP

    Guys, looking for some urgent help on a cb24 dhw diagphram basically went to one today, changed flow switch didnt work, stripped dhw flow diagphram section, found nowt wrong and put it back together the way I thought it should go, (METAL SIDE FACING OPPOSITE SIDE TO DIVERTOR SECTION...
  12. M

    Worcester Bosch 24i not firing from timer.

    had a problem lately where the C/H would not fire up on timer on or auto but fired once I turned tap on . changed the thermisters and it solved the problem, both thermisters showed correct readings but worcester advised this and it worked a treat, I orginally thought PCB as well but this was...
  13. M

    Worcester 24i combi boiler problems

    the 24i's got a built in bypass ! had problems before with Trv's truned down and boiler kettling as bypass is not very good for c/h but never on DHW demand only.
  14. M

    vokera excell 80 sp Divertor valve problem

    cheers mate ! how time consuming is this for the lot though ?? and is there a best way like DV first or DHW diaphram ? nothing worse than doing something the long way !
  15. M

    Hot water allways on

    sounds like a valve problem, if the boiler is firing without demand then this is most likely, very common for the valve body to stick and both the electrical and mechanical parts can be effected , then again could be as simple as his immersor is left on at his tank if he has 1 !!!
  16. M

    Potterton Puma - Rads getting warm on H/W.CH off

    had this once before where the wax capsule is sticking and possibly not seating right inside the valve, full valve replacement is a pain so best to try the capsule first and make sure it seats correctly when fitting. most common problem with these are no heat as the valve sticks in H/W...
  17. M

    vokera excell 80 sp Divertor valve problem

    Guys, got a passing divertor valve on a 80SP VOKERA. Had this problem with a linea and got the service kit, pretty basic repair. got the kit for the EXCELL / ECLIPSE and just wondering as it comes with the diaphrams etc, do I just replace the divertor section and how easy is it to do so...
  18. M

    puma 80e low system pressure

    yes strange that how the combi 80 is basically a puma80e minus the WPS and temp control knobs !! the WPS being left out was strange !!
  19. M

    IDEAL CLASSIC FAN ISSUE

    are all classic 1 's perm pilot ??
Back