  1. M

    puma 80e low system pressure

    does the sae job yes.. goes without saying to tape up the end disconnected however as we all know short term method till either fixed or replaced !!
  2. M

    puma 80e low system pressure

    most likely the lowpressure switch is blocked with sludge, very common... easy fix, drain boiler remover switch, clear and put back on.. clean switch and connection but pushing a small thin screwdriver through the hole at the connection and the back of the switch (be carefull with the switch...
  3. M

    IDEAL CLASSIC FAN ISSUE

    as these boilers I am questioning are on a Housing association contract then looks like nobody is getting ripped off then doesnt it !! PS. whats the classic 1 and classic 2 ?? the models I have been working on do not state 1 or 2 all are FF240 OR FF250'S !!
  4. M

    IDEAL CLASSIC FAN ISSUE

    will keep that in mind if we start replacing mate ! just thought these didnt actually do much for protecting the fan as we have replaced that many fans on these boilers, some with these propellors and some without and every one was as Tony said above, very brittle at the connections etc...
  5. M

    IDEAL CLASSIC FAN ISSUE

    Tony noticed that also on these boilers, probably due to the position of the fan being directly above unlike many which sit to the side slightly.. fan replacement quite common.. weve not been replacing the broken/ brittle propellors purely for the reason every 1 is so brittle and broken...
  6. M

    Vokera Compact 24 Pressure Going Up.

    deffo sounds most likely the heat exchanger !! if you shut off the cold supply to the boiler and it doesnt rise when the boiler is idle but rises when idle and cold supply open this is your fault.
  7. M

    IDEAL CLASSIC FAN ISSUE

    Guys, been to a few ideal classics lately and as most will know the fans have a small plastic propellor on the top, for cooling purposes to the fan motor I would presume ? anyway as most will know/ have seen these plastic propellors all tend to go brittle and break off thu time Just...
  8. M

    TESTING FOR INHIBITOR

    cant think of any other reason someone would ask about inhibitors and cost of repair around this price ! still I dont think a bottle of sentinel is gonna sort this issue out !
  9. M

    TESTING FOR INHIBITOR

    I know that and Im not saying it make a difference to the contract if this is the case .. I JUST PERSONALLY THINK this is why the question of Inhibitors and £1000 bill to fix the problem would come from ! is that not what BG charge ??
  10. M

    TESTING FOR INHIBITOR

    It sounds to me this is the powerflush fee from someone like BG !!! and its actually sludged due to no previous inhibiter fitted etc !!
  11. M

    TESTING FOR INHIBITOR

    I use the sentinel one for my company and it aint restricted to sentinel chemicals !
  12. M

    New Combi Boiler Location?

    if its suitable via the regs then your the customer and you tell them what you want done, simple as that !! there may even be people on here in your area than would like the job if this guy doesnt !!
  13. M

    BAXI 80E COMBI RISING PRESSURE

    quite aware checks required mate, wasnt at the boiler myself, just asked about the symptons and to be honest the DHW HEAT EXCHANGER was suggested. Once he carried out the checks I suggested this was the best conclusion I could come to without actually being there to diagnose. Cant think of...
  14. M

    BAXI 80E COMBI RISING PRESSURE

    Tony yes it was at the isloation valve at the boiler inlet.. When he also adjusted the mains stopcock to reduce incoming pressure the rise in pressure slowed down and vice versa ! what other causes can there be ??
  15. M

    BAXI 80E COMBI RISING PRESSURE

    cheers mate.. appreciate the quick reply.. will let him know to go ahead and replace...
  16. M

    BAXI 80E COMBI RISING PRESSURE

    Guy's .. quick one for you's.. Mate called tonight at a Baxi 80e combi.. hes an engineer but works on Meter installs so not into FF... PRESSURE WAS RISING... Usual checks of exp vessel done, called me back saying pressure was rising when system not running, advised to check filling loop...
  17. M

    Potterton Puma 80 will not switch on

    would agree its most likely the pcb cost abput £80 if it is... could also be the pump has blown the pcb fuse and only a pump replacement required.. first thing I would have looked at is the fuse then pump and also the pcb for the above mentioned...
  18. M

    rads on all the time!!

    if you really dont know what a zone valve is m8, call a plumber / heating engineer. or better still get someone from here to sort it for you if any one is local to you. what kind of boiler do you have (make/model) incase its a divertor valve problem and not actually a zone valve !...
  19. M

    rads on all the time!!

    souns like a passing or faulty zone valve, replacement required !
  20. M

    Repair hairline crack in radiator

    try leak seal.. if it doesnt work, new rad