  1. R

    Consumer Unit layout

    Loft is just feeding a) TV Aerial Booster b) Alarm Bell Box c) Later hopefully Linux SAN box
  2. R

    Consumer Unit layout

    The house is currently wired such that the house sockets are all on one ring. To split it would require a complete rewire from what I have seen Yes Part-P has been considered
  3. R

    Consumer Unit layout

    How does this sound for the layout of my new CU.. Unprotected Loft Feed 16 Imersion Heater 16 Alarm 6 DoorBell 6 Downstairs Lighting 6 Upstairs Lighting 6 External Lighting 6 Protected 80A 30mA RCD Garage (Proteced it self) 32 Power Ring 32 Power Shower 16...
  4. R

    Strange Extra Fuse Box

    After having a good poke around this morning i indeed found another set of tails tucked just above the outside access box for the meter so it looks like it was a fusebox for economy elecy. Now just need to find where the cables lead to see if I can just cut and tape them up or if they need to...
  5. R

    Strange Extra Fuse Box

    The reason its like that (guessing at least) is that the far right hand fuse is the cooker supply which is fed by 6mm2 cable i.e. it could be a 30Amp fused circuit if it wanted to be but as they did not need 30A they have put a 15 amp in
  6. R

    Strange Extra Fuse Box

    PIR? I am looking to get a replacement split load CU put in so I can put in seperate circuits for the shower, door bell and alarm and new power to the loft
  7. R

    Strange Extra Fuse Box

    I need to get my Multimeter out to check if the tails are live. 1 only have 1 meter. Now that you say that they probably were both connected when the house was built ~35 years ago as you say but now only 1 is used..
  8. R

    Strange Extra Fuse Box

    Got a strange extra fuse box and can't work it out.. Box on the left has fuses and is supplying power to everything in the house. Box on the right (one shown close up) is connected with tails BUT no fuses and turned off. Looking at it two of the fuse blocks are connected to cables which go...
  9. R

    Am I being thick?

    I am in the middle of installing my kitchen. Looking at how to connect up the waste system for the sink and am having a thick moment. Pic 1 shows the setup I have Pic 2 shows a "Flexiwaste Connector - Compression System" with one of the nuts from the end of the U-Bend. The pipe fits...
  10. R

    Replastering required before retiling?

    I am redoing my kitchen at the moment. The old tiles have been removed. Before retiling am I going to have to replaster the wall before retiling or can I just put the tile adhesive on a bit thicker to make up for where the top skim has come off? This is a picture showing the sort of surface...
  11. R

    Single light switch controlling 2 lighting circuits

    In my living room I currently have a single light which is controlled by a single switch. I have put in a number of halogen lights which now all trigger off the single switch I am looking to put some X10 control onto these lights such that there are two circuits: Circuit 1 controls 3...
  12. R

    Extending Chimney Breast - Plastering Question

    I have a small chimney breast in my new house - more a flue than chimney. It is only 1 brick deep from the back wall, but unfortunately its not in the middle. As i am putting an LCD on it i want to make it look central to the room. I am planning to extend it to one side by around 250mm using...
  13. R

    My living room AV install. Work in progress with pics.

    I am planning to perform an installation just like this one so can I just clarify how it 'should' be done to comply with all regs etc 1) The cables going to the chimney breast should have been taken up to the ceiling, across through the ceiling/floor boards and then down the front of the...