Search results

  1. 1

    Condensing Boiler secondary pump

    You can turn the pump 'up' on this boiler from speed one to two, try that first, could there be any issue with sludge in system?
  2. 1

    Faulty TRVs

    Edit
  3. 1

    Highflow 400: Inhibitor in hot water supply!

    Could try a mechanics stethoscope, pretty cheap to buy and good for pinpointing noises
  4. 1

    Faulty TRVs

    The flow direction through valve is wrong. Causes them to knock as they are about to shut off, depending on style of trv you can simply turn them round otherwise you will have to swap them to the other side. Beat me to it!
  5. 1

    Highflow 400: Inhibitor in hot water supply!

    If he depressurises the heating system and then turns on cold water it may be possible to hear where the water is getting in. The manifolds that connect to the plate heat exchanger would be the only other place. They are plastic and suppose a small crack in the pathways could be the cause.
  6. 1

    Luke warm water..Pipe hot?

    Could there be anything on the hot and cold pipe work that is causing the hot and cold water to mix. You could t in a connection below boiler on the hot pipe to confirm hot water at that point. If its ok there then you have to look further down stream. Try the hot water pipe further away from...
  7. 1

    Noisy central heating pipes (ecotec plus 428)

    Hi, Would say the 4:30 thing is possibly a faulty zone valve. Is the boiler now on all the time without demand? If the pies are rubbing up against wood the only way to sort it is to get to them I would think, had one job once that we took down part of the ceiling below to get to pipes, it...
  8. 1

    Cold Radiators – desperate for help!

    Did the rads heat up b4 boiler change? Have they been ok after boiler change and got worse? For whatever reason seems like a circulation problem, was the system flushed?
  9. 1

    Pootterton Suprima 60 not firing..soot near flue

    Regardless, get it checked and made safe, cant be sure but yiu could end up with explosive ignition if you keep trying to light it. As for being ripped off ask freinds or family for recomendations.
  10. 1

    Pootterton Suprima 60 not firing..soot near flue

    Turn boileroff now and call your gas emergency provider. They will call out free of charge and make boiler safe within two hours max. Then get it looked at by a registered installer. Dont muck about with this.
  11. 1

    Boiler keeps cutting out please help

    The boiler isn't a condenser, when is it cutting out, do you mean the pilot is going out or the main burner?
  12. 1

    Vaillant 828E TurboMax Combi Boiler Pressure Gauge Problem

    glad to hear it. thanks for posting to let us know. cheers
  13. 1

    Groaning boiler !! Savio/Biasi 428S

    I would have described fan noise as more of a rattling than a groaning. In 22 years at this I've never heard a fan on an se boiler groaning. Question for the op does it sound a bit like a plane landing?
  14. 1

    Groaning boiler !! Savio/Biasi 428S

    Joe just cause your boiler did it doesn't mean this one is doing it. To state that is definitely the problem is ridiculous. We can all only offer advice here as none of us are standing in front of the boiler. Perhaps the op could post when boiler fixed to confirm fault and we will see.
  15. 1

    Boiler gargling noise

    Does sound like its just the water making its way into exp vessel, if the vessel was empty of water and no charge when the system is pressurised the air in it will be trapped. The water then could bubble into the vessel as the air is under pressure. The diaphragm in the vessel was probably...
  16. 1

    Air in Magnaclean Filter

    Flush it properly with chems and treat with inhibitors after making sure no leaks. If you can get the magna clean on the return. Badly sludges system can produce loads of gas. Cheers
  17. 1

    Vaillant 828E TurboMax Combi Boiler Pressure Gauge Problem

    Could there be a blockage at the connection for the pressure gauge. Drain again, disconnect gauge and stick something in the hole to clear.
  18. 1

    Air in Magnaclean Filter

    Are you sure it's air? It could be hydrogen gas building up if system water isn't treated properly. The manga clean might as well not be fitted imho as its not protecting the boiler. Other possibilities are weeping joints that could pull air into system rather than leak water out??
  19. 1

    Boiler gargling noise

    This could just be the old exp vessel filling up with water, can't think of anything else that would cause a gurgling noise. Is the pressure gauge flicker happening when the gurgling noise happens. It's not necessary to disconnect the old vessel. Is the pressure ok, ie it doesn't go too...
  20. 1

    Rads not heating unless TRVs on high level

    As johnd says if the room temperature is above set point on thermostat the rad won't heat or will be Luke warm. If you turn it to 5 and rad gets nice and hot circulation is ok.