    Hot Water won't run if Heating is on

    check to see what voltage is on the orange wire when hot water on. if its not 240vac then work it back through the cylinder stat to the programmer to see where the fault is. You can also check to see what voltage is going to the syncron motor when heating and hotwater on. heating is power to...
  2. 1

    Relacing Faulty Salus rt300rf Wireless Thermostat

    bit unsure how its been wired but what you should have on the old one for a 240vac system is live and neutral connected, live to the common and then SL on connected back to the boiler, NO on your new salus. regardless of weather its 240v or low voltage something needs to go into the common so...
  3. 1

    Relacing Faulty Salus rt300rf Wireless Thermostat

    Is there not a comm on the faulty one?? NO is SL on
  4. 1

    Luke warm/cold radiators no pressure increase when boiler on

    ok, def a restriction in flow somewhere, trouble is finding it!! How long has the cleanser been in, what have you used and is the concentration right?
  5. 1

    Central Heating Prevents Hot Water Coming On

    The 2002 was bad for the slider switches not working after a while, sometimes its the contact on the back of the switch that gets bent in and doesnt make. However, you seem to suspect that the plumber has done something wrong? If hes been mucking about with the wiring its possible hes not wired...
  6. 1

    Salus RT500rf wiring.

    boiler runs less than 200 watts. cant see it burning out a wire. I always replace this wire anyway as I find it better to twist a couple of stranded wires together for the terminals. I can understand the instruction for the link wire but in this instance there's very little current going through...
  7. 1

    Salus RT500rf wiring.

    Just the same then! When you say existing clock is that on the boiler or external? If fan and pump on is the boiler firing gas?
  8. 1

    Salus RT500rf wiring.

    It's an older 28 I, RL goes to live on salus, Link live to common on salus. No on salus back to RI on boiler RN to neutral on salus. I don't think you have salus controller powered up. Edited to say, leave existing timer on boiler on constant or disconnect it. The No might also be...
  9. 1

    Salus RT500rf wiring.

    Is this a junior boiler or just 28i ?
  10. 1

    Salus RT500rf wiring.

    If it was ok before then its got to be the wiring or a faulty salus. Tried using this make before but had no end of trouble with them. Just make sure the remote is switching the receiver on/ off . You only need three wires to the receiver box from the boiler, Ls on boiler to live on receiver...
  11. 1

    Salus RT500rf wiring.

    can you tell us what 28i it is, greenstar? older junior/ rsf.
  12. 1

    Luke warm/cold radiators no pressure increase when boiler on

    Just a quick check to do, with all radiators on does the return pipe at boiler get hot even though rads are cold??
  13. 1

    boiler turns on and off

    probably air in it, can you tell us what model ?
  14. 1

    Biasi 24s buzzing - no ignition

    somethings stuck, its a job for gas safe registered chap though, one of the parts is inside combustion chamber so please dont diy, switch off power to boiler engineer might be able to save part if its not already burnt out. get it serviced.
  15. 1

    POTTERTON PUMA 80E - WATER FROM AIR VENT & LOCK OUT

    Very true, glad im not the only one thats done that :oops: Done it once years ago. Spent more time cleaning up than fixing the boiler!!
  16. 1

    POTTERTON PUMA 80E - WATER FROM AIR VENT & LOCK OUT

    Think the valve is on the side of that one. Have a look at the rear, it's there somewhere. Might be that it's goosed anyway considering the age of this boiler now. You could fit an aftermarket one to return pipe for a faction of the cost of the manufacturers one. You also need to check the...
  17. 1

    Worcester 28CDI difference between heat exchangers

    Feck, I'm getting out of here before there's a fight. :wink:
  18. 1

    logic + 30 possible cycle problem

    Hi, does the boiler fire gas during this time?? Or is it just the pump running. Boilers have a pump or fan overrun to cool themselves after the heating demand stops so might just b that. If there is fairly short spells between the thermostat calling for heat then it may be the boiler never cools...
  19. 1

    Worcester 28CDI difference between heat exchangers

    Gas to water only has system water in it ie the water in your radiators. Water to water has the system water heated my the gas to water exchanger on one side and the cold mains water on the other side. System water passes its heat to the cold water and hot water comes out other end.
  20. 1

    MX shower tray cracked

    hi all, new to this forum and was looking for some advice please. I recently fitted an MX element tray, 1200 x 800 quad with the riser kit and my customer has noticed a crack appearing going from the waste hole towards the back corner. The tray and riser kit are both supplied by mx. The...