    UFH flow & pressure

    My 17 year old Polyplumb UFH system is showing some reduction of flow across some of the ten loops (based on flow meter readings and getting one room in particular up to air temp) I am also finding little movement in flow between some of the balance valves being fully open / closed so I have...
  2. C

    syncron motors

    Thanks oilhead, Do you have any info that would help me find this part?
  3. C

    syncron motors

    I am looking for a syncron motor (type used in zone valves) that has a slightly longer gear shaft than the ones used in Honeywell valves. I have a actuator on my "boiler" diverter valve that is driven by above but I am struggling to find a replacement, I know there is motors out there as I have...
  4. C

    UFH manifold issues

    Thanks for your reply, the flow meter / valves are on a polyplumb manifold listed at around £13 ea so I will get some after the holiday period. The actuators are Honeywell Z100 BGE that are now replaced with an updated version MT4 230S-NC (£40 incl del) and there are not many listed on Google so...
  5. C

    UFH manifold issues

    Please advise, I am finding the following issues with some of the 10 circuits on my 17 year old UFH system: Of the ten circuits (seven zones) there are two actuators that are allowing flow (max 1 lt/min) on no demand and two flow valves that are showing restricted flow on demand (around 1<2...
  6. C

    wardrobe door hanging

    I have seen some kitchen cupboards at the above measurements, the doors being 32x60mm tulip framed with 18mm MDF centres with standard hinges in a 32x60mm face frame. The concern for me is the lack of adjustment in the hinge. If I went down to a 22X60mm door frame out of popular with 12mm MDF...
  7. C

    wardrobe door hanging

    With the doors being “inset” not overlaid And being32mm thickness I assumed euro was out of the question Would I be looking for a specific hinge Thanks Paul C
  8. C

    wardrobe door hanging

    With the doors being “inset” not overlaid And being32mm thickness I assumed euro was out of the question Would I be
  9. C

    wardrobe door hanging

    I am planning to build a set of wardrobes veneer faced cabinets with painted MDF framed doors inset in a painted face frame (shaker stile) I was thinking 32mm X 60mm wardrobe face frame and 32mm X 60mm door frame with 18mm inset MDF. (six cabinets at 650mm width X 2200mm Height X 600mm depth) My...
  10. C

    Faulty UFH TMV?

    Please advise, With the UFH mixing valve set to give 45^ Flow temp To the manifold circuits am I right to expect this temprature To remain constant whatever the flow rate, if any, there is to those circuits? Thanks
  11. C

    UFH manifold TMV control

    One valve has settled down at 46* (the height of the spindle protruding the valve casing measures 5mm) and working ok. The other, with the valve set to minimum, is at 56* (spindle fully in and is 3mm from valve casing) The pump arrow is showing correct direction, pumping water to the "hot"...
  12. C

    UFH manifold TMV control

    Thanks for the response. The UFH kit was supplied by underfloorheating1.co.uk at Carcroft Doncaster I have not got the details of the TMV manufacture but there is a photo attached showing the System installed. I have checked the flow & return circuit and all seems ok. Looking at the attached...
  13. C

    UFH manifold TMV control

    I have a problem with a new installed UFH system as follows. One 46kW oil boiler heating two number 12 port manifolds plus DHW and rads and I am having difficulty controlling the TMV on both manifolds. Having set both manifold mixing valves to around 45* the TMVs don't hold that temp.they both...
  14. C

    Underfloor Heating - A couple of issues

    Tony, with regards to the water side issues I think there is some useful info. in the threads above to work through. I would start a new thread in the electrical forum section explaining the action of the pump and appending the above wiring diagram. The electricians are always discussing CH...
  15. C

    Underfloor Heating - A couple of issues

    The zone valves purpose is to close off flow to the manifold when demand is met, it stops the boiler and pump electrically and closes the flow of water to that manifold. The system controller (programmer) can do the electrical part, when a stat calls for heat and the programmer time clock allows...
  16. C

    Underfloor Heating - A couple of issues

    Andy You have two manifolds, I presume two separate systems UFH ground floor with a controller (programmer) in the living room. UFH first floor that will also have a similar programmer and stats controlling the first floor circuit? Both manifolds have pumps attached (as your photo above) so...
  17. C

    Underfloor Heating - A couple of issues

    Andy, Re above dismantling zone valves apparently some do and some don't dismantle without getting wet. Paul
  18. C

    Underfloor Heating - A couple of issues

    Hello Andy, I think you might have given part of the answer to your utility heat problem as above. Could it be a combination of factors, poor / reduced flow and the above quote. ((remove the actuator (which is on the return flow) and set the kitchen stat high to establish what heat you can get...
  19. C

    Underfloor Heating - A couple of issues

    Andy, As far as the design temp of the system is concerned the real problem, I believe, is ensuring that the temp. at the screed does not damage floor covering (some tile and all hard wood floor suppliers specify a limit around 28*) so running the system at 50* shouldn't be an issue. (The...
  20. C

    Failed TMV with UFH

    The UFH blending valves (TMV) are not fail safe! I asked Reliance technical as there literature states that they are but said it only applies to a open ended water system as in hot water taps or showers etc. They told me they were sending a valve out out on the day I found the fault (leaking...