Search results

  1. J

    Scantronic 9800 - Explanation of Zones A, Part Set B & C

    On the 9800, A is the full set, B and C are the part sets. The LED's will illuminate when that current part set is armed. With regard to the zoning, a contact should be placed on the front door, as this can end any excess exit time, and arm the system. If you have to pass any detectors, they...
  2. J

    Wireless Alarm advice needed please.

    I know this doesn't cover it all, but its much better than the yale, and fairly easy to install: http://www.e-fireandsecurity.co.uk/visonic-powermax-new-version-wireless-intruder-alarm-kit-2/p10...
  3. J

    Viper GLX - first to alarm option

    Its to do with when your having more than one viper on the same zone. It requires at least 7 cores. Two for power, alarm cct, and tamper cct, then you have a switch wire. Say there are 4 vipers on one particular zone, the first viper that activated will flash, subsequent vipers will be...
  4. J

    Scantronic 9751: "Rst Code"/"Can't reset&quot

    Your panel is asking for a remote reset. By default these panels are on engineer reset on end station tamper, but the installer has obviously selected the remote reset on tamper as well. You'll need to contact the original installer, as you might still have a service contract or monitoring...
  5. J

    Veritas remote keypad

    I think you have to program old veritas sounds, used with older keypads. Its under one of the misc selections menu's.
  6. J

    Quick Veritas Excel Question.

    The RKP's backlights are on all the time. So quite simply, no.
  7. J

    Bellbox Tamper

    Normally, a bell tamper consists of a 0V feed, goes through the switches and comes back and connects to the return terminal of the control panel. What bell box have you got and what control panel?
  8. J

    What PIRs are these

    http://www.riscogroup.co.uk/Products.aspx?subcatid=165&id=20
  9. J

    Texecom Veritas R8

    AFAIK, the external sounder cannot be changed when a fire zone is triggered. You probably pulled one of the wires out for the bell trigger. Try doing a bell test, and see if it works.
  10. J

    Accenta 6 Burglar Alarm - No Code

    Yes it does Yes, but it can be silenced if you have the correct code. try it and see. Thats the engineers code. 0123 is the default user code. You did say that the day light was off. This would indicate that the system is set. If i was you i would get an engineer in who would be able to...
  11. J

    Tag alarm restore required

    What system is it? you may have blown a fuse when moving the pir.
  12. J

    Scantronic 9448+ internal alarm and tamper light

    Spider wouldn't have set a tamper alarm off. Have you actually tried resetting the system? enter your code to reset or if you haven't got a code try 1234. It might get rid of the tamper light. To change the battery, open panel, enter code to silence, remove old battery and replace with...
  13. J

    Scantronic 9448+ internal alarm and tamper light

    You definitely need a new battery if it hasn't been used in 13 years, they only last about 5!! this one would do fine: http://www.e-fireandsecurity.co.uk/2-4ah-12v-alarm-battery-rechargeable-sealed-lead-acid-battery/p260 With regard to the tamper, have you had any new carpets recently...
  14. J

    Honeywell ADE G4 mini - can't set timed entry

    According to the manual: "Entry Time This is the time allowed to enter the premises via the entry route and unset the system. The programmable range is 00-99 seconds. The actual time is multiplied by 10 00 = 5 seconds 01 = 10 seconds 03 = 30 seconds 99 = 990 seconds (16.5 minutes)
  15. J

    how can stop alarm when I cut electricity

    You need a new battery. A 2.1Ah one. http://www.e-fireandsecurity.co.uk/2-4ah-12v-alarm-battery-rechargeable-sealed-lead-acid-battery/p260#tdesc_1
  16. J

    Scantronic 9448 old 9 1/2 yrl old version

    tbh, i don't think any 9448's have the option for an engineer reset on tamper.
  17. J

    Accenta G4 LCD Remote - Difficulty Programming Zones

    Don't you have to press SET to save the changes you've made in the menu? Just a thought.
  18. J

    Premier 24 status display

    Will do, thanks for the advice!
  19. J

    Premier 24 status display

    That is correct, no connection to ARC. Does turning off EN50131 do anything else, other than enabling the LED's. Thanks
  20. J

    Premier 24 status display

    Anybody know how to get a premier 24 to display its status permanently i.e the ready and info led's, rather than hide them until a code or prox tag is put in/swiped? Thanks